posted to rec.boats.cruising
|
|||
|
|||
![]() "GBM" wrote in message ... Two questions: 1. Remote Solenoid switch My Seaward propane switch is powered from the main panel supply. But this could be a potential safety problem. If the main panel switch/breaker trips or is accidentally switched on and off, the propane solenoid will switch on and off and could cause propane to flow to an unlit stove. Should the propane switch be hot wired from the house battery? 2. Propane Detectors My propane detectors (have two) are powered from a fused switch on the main panel. This means we must remember to turn them on before activating the propane solenoid. Should the detectors be: - hot wired to the battery like bilge pump (not good because of continuous battery drain.) - wired to main battery switch (so they come on whenever we have power turned on from house batteries) - wired so they activate when solenoid switch is turned on (probably not good due to start-up delay in detectors.) Does ABYC address this? How are modern boats wired for propane? (OK - that two more questions ![]() GBM My Seaward propane switch You mean solenoid, not switch, correct? You can't connect the solenoid directly to any battery without first putting in a switch. Having the solenoid activate whenever you switch on the main panel does not sound like a good idea. You are not going to have gas coming out of the stove unless someone has left a burner turned on but this could happen. I would put in a switch on the main panel or a switch at the stove. If you want to be real safe put in two switches, one at the master panel and one at the stove. You can be even safer by spending lots of money and buying a new stove that has safety shutoffs on all burners. The propane detector I have draws something like 0.1 amps. I don't think I would worry too much about connecting 2 of them directly to a house bank. A small solar panel would take care of this draw. |
#2
![]()
posted to rec.boats.cruising
|
|||
|
|||
![]() "Gordon Wedman" wrote My Seaward propane switch You mean solenoid, not switch, correct? No Gord - I did mean switch. I have a Seaward mini panel that includes the switch and a fuse - it is mounted in the nav station which is near the galley. When switched it activates the solenoid that is in the propane locker. GBM |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Propane system foul-up | Cruising | |||
Grant's Tomb Questions... | General | |||
Vacuum sealing propane canisters | Cruising | |||
Need a Good Book on Basic Wiring in a Boat For Beginner | General | |||
wiring help | General |