Noise and generators
"Paul Squire" wrote:
In addition to plugging up all the holes, you should make sure that the surfaces surrounding the noise source are soft (not hard and reflective) and bumpy. For instance if you have a cement block wall that is unpainted, it will be better than one that is painted because the paint fills in all the holes and reflects the noise back into the room. I've heard of fero cement hulls, but concrete block????? What sort of mortar do you use? What shape hull can you build? ;-) I was just using that as an example. Sometimes you can use the tiles from a dropped ceiling as sound insulation on the walls. grandma Rosalie |
#22
|
|||
|
|||
Noise and generators
Hi, Charles, and group,
"Charles T. Low" wrote in message news What electrical loads qre you planning on carrying? We don't yet know for sure. There's some stuff which needs attention, and some other stuff we expect to buy. In any case, I'm not happy with the amount of charging provided by the engine, which we ran for an awful lot of the time on our shakedown/delivery cruise, and still found ourselves not fully charged most of the time. Otto (the autopilot) is so hungry we basically didn't use him, preferring to go with Manny (Manuel Steering) most of the time, due to the drain. FWIW, the batteries, 4xT105, are pretty new. Could you get by without a generator? No doubt - but only at the expense of installing a solar and wind farm, which, actually, is our preference. As noted in another post, humorously observed by Larry, but seriously by Bill, we'd readily consider selling it, as it would enable our conversion. We'll be in the tropics, where sun and wind are abundant. L8R Skip and Lydia |
#23
|
|||
|
|||
Noise and generators
On Wed, 23 Jun 2004 00:55:23 -0400, "Skip Gundlach"
wrote: I'm not happy with the amount of charging provided by the engine, which we ran for an awful lot of the time on our shakedown/delivery cruise, and still found ourselves not fully charged most of the time. =================================== Do you have a heavy duty alternator (100+ amps) with a 3 stage regulator? If not, that's the answer. The bad news is that you'll need dual belts to drive it, but well worth the investment. |
#24
|
|||
|
|||
Noise and generators
You can go up to a 160 amp alternator without having to
resort to a large frame dual belt model. Doug s/v Callista "Wayne.B" wrote in message ... On Wed, 23 Jun 2004 00:55:23 -0400, "Skip Gundlach" wrote: I'm not happy with the amount of charging provided by the engine, which we ran for an awful lot of the time on our shakedown/delivery cruise, and still found ourselves not fully charged most of the time. =================================== Do you have a heavy duty alternator (100+ amps) with a 3 stage regulator? If not, that's the answer. The bad news is that you'll need dual belts to drive it, but well worth the investment. |
#25
|
|||
|
|||
Noise and generators
On Wed, 23 Jun 2004 08:50:10 -0400, "Doug Dotson"
wrote: You can go up to a 160 amp alternator without having to resort to a large frame dual belt model. ======================================== Doug, can you cite some references on that? I've never heard of anyone recommending 100+ amps without dual belts. I used to run a 120 amp Balmar on one of my old sailboats with a single belt. Frankly it left a lot to be desired even at 50 to 60 amps - lots of squealing and chewed up belts. It would never get even remotely close to 100 amps, even for short periods. The belt slip was just too much for it. |
#26
|
|||
|
|||
Noise and generators
In article ,
Wayne.B wrote: Doug, can you cite some references on that? I've never heard of anyone recommending 100+ amps without dual belts. I used to run a 120 amp Balmar on one of my old sailboats with a single belt. Frankly it left a lot to be desired even at 50 to 60 amps - lots of squealing and chewed up belts. It would never get even remotely close to 100 amps, even for short periods. The belt slip was just too much for it. Ok here we go with the Math...... 120 amps @ 13.6Vdc = 1632 Watts figure that you alternator is say, oh 75% efficent that equals 2175 watts of input energy, which equals 2.916 Horespower. Now 3 HP thru one belt? Well, it can be done with a C size belt, but most engineering folks like to spec max 1.5 HP per belt. So two belts would be prefferable for 3 HP worth of work. The above assumes Vbelts, and not gear-belts which can easily handle up to 6 HP with no problems. There are belts and there are Belts, so lets get the definitions set down first...... Bruce in alaska who is running a 6 HP air compressor on a 2.5 inch gearbelt off my 4-108 Perkins 10Kw genset -- add a 2 before @ |
#27
|
|||
|
|||
Noise and generators
All I can cite is the fact that I have run a 160 amp alternator
on a single belt for about 4 years. No slip, no squeel, and full output when needed. No problems with bearings and still on the original belt, although I have a couple of spare belts due to the heavier stress expected. Very happy so far. I would use a dual belt unit if my space would allow it. Doug s/v Callista "Wayne.B" wrote in message news On Wed, 23 Jun 2004 08:50:10 -0400, "Doug Dotson" wrote: You can go up to a 160 amp alternator without having to resort to a large frame dual belt model. ======================================== Doug, can you cite some references on that? I've never heard of anyone recommending 100+ amps without dual belts. I used to run a 120 amp Balmar on one of my old sailboats with a single belt. Frankly it left a lot to be desired even at 50 to 60 amps - lots of squealing and chewed up belts. It would never get even remotely close to 100 amps, even for short periods. The belt slip was just too much for it. |
#28
|
|||
|
|||
Noise and generators
How many amps do you actually get from the alternator, and how big is your
battery bank? I have a 100 Amp alternator, but it hardly ever does more than 84 Amps into a 425 AH bank. "Doug Dotson" wrote in message ... All I can cite is the fact that I have run a 160 amp alternator on a single belt for about 4 years. No slip, no squeel, and full output when needed. No problems with bearings and still on the original belt, although I have a couple of spare belts due to the heavier stress expected. Very happy so far. I would use a dual belt unit if my space would allow it. Doug s/v Callista "Wayne.B" wrote in message news On Wed, 23 Jun 2004 08:50:10 -0400, "Doug Dotson" wrote: You can go up to a 160 amp alternator without having to resort to a large frame dual belt model. ======================================== Doug, can you cite some references on that? I've never heard of anyone recommending 100+ amps without dual belts. I used to run a 120 amp Balmar on one of my old sailboats with a single belt. Frankly it left a lot to be desired even at 50 to 60 amps - lots of squealing and chewed up belts. It would never get even remotely close to 100 amps, even for short periods. The belt slip was just too much for it. |
#29
|
|||
|
|||
Noise and generators
On Wed, 23 Jun 2004 23:33:42 -0400, "Doug Dotson"
wrote: All I can cite is the fact that I have run a 160 amp alternator on a single belt for about 4 years. No slip, no squeel, and full output when needed. =================================== What kind of alternator and what kind of belt? |
#30
|
|||
|
|||
Noise and generators
Battery bank is just under 600AH. Alternator is rated 160A cold,
but 147A hot which is the actual useful output. I've seen it put out as much as 120A, but that was on purpose to test it out. I don't normally let the batteries get low enough to require such high currents. Normally charge using the genset to power a 110A shorepower charger. Doug s/v Callista "Jeff Morris" wrote in message ... How many amps do you actually get from the alternator, and how big is your battery bank? I have a 100 Amp alternator, but it hardly ever does more than 84 Amps into a 425 AH bank. "Doug Dotson" wrote in message ... All I can cite is the fact that I have run a 160 amp alternator on a single belt for about 4 years. No slip, no squeel, and full output when needed. No problems with bearings and still on the original belt, although I have a couple of spare belts due to the heavier stress expected. Very happy so far. I would use a dual belt unit if my space would allow it. Doug s/v Callista "Wayne.B" wrote in message news On Wed, 23 Jun 2004 08:50:10 -0400, "Doug Dotson" wrote: You can go up to a 160 amp alternator without having to resort to a large frame dual belt model. ======================================== Doug, can you cite some references on that? I've never heard of anyone recommending 100+ amps without dual belts. I used to run a 120 amp Balmar on one of my old sailboats with a single belt. Frankly it left a lot to be desired even at 50 to 60 amps - lots of squealing and chewed up belts. It would never get even remotely close to 100 amps, even for short periods. The belt slip was just too much for it. |