On Sat, 05 Mar 2005 17:31:30 -0800, Walt Bilofsky wrote:
Has anyone had experience trying to drive a Xantrex inverter/charger with a small gas generator? I tried it with little success. I tried to run a Statpower 40 (40Amp) charger with a Honda 1000. 40A at, say 15V is 600W, and Xantrex say they're about 90% efficient, so no problem, right? WRONG! Talked to the designers (right here in Burnaby, BC, it turned out), and the problem is the Power Factor: about .6!! so it's drawing around 11A at 120V: too much for my poor genset! Looking at an EU2000 to drive it, but too many other things to spend money on right now... Lloyd Sumpter "Far Cove" Catalina 36 |