On Tue, 7 Mar 2006 08:09:06 +0100, "Meindert Sprang"
wrote: "Len" wrote in message .. . With a 1000 Ah Bank, with batt charge status say at 60%, voltage in bulk stage is 14,4, current from the wind genny is say 15 amps. In that case I'd' like the additional 12 amps from my solar panels to help doing the job I put them up for, but the regulator keeps them form doing so. Hi Len (I'll answer your e-mail later), I don't think that the voltage is 14.4 at 60% charge. The 14.4V is the point where the bulk charge should stop. But during the bulk stage, the voltage slowly rises from whatever value to 14.4V while the current is say 15A. during that period, the current from the solar panels could contribute but the moment the voltage reaches 14.4V you're at about 80% charge and the system should change to equalize stage with a voltage of 13.8V. Meindert Okay..... thanks.... I needed that..... I was (obv. erroneously) convinced bulk charging was executed by forcing a voltage of 14,4 v... So... (your remark is slowly being processed and internalised), there is no "competition" between sources or regulators whatsoever, right up to the moment the battery reaches a 80% charge? I am looking forward to your email.... :-) Len. |