Matt,
Have you thought about this scenario? You accidentally leave the propane on when you leave the boat, or someone else turns it on after you leave. There is a really small leak, but in three weeks a fair amount of propane collects down in the bilge. You come back and open the boat up just like always, and reach down and turn on your sniffer. The small spark from the switch closing ignites the propane (BOOM). The only way I can see to avoid this scenario is to have explosion proof switches, (But then your bilge pump auto switch might set it off), or to have an always on bilge vent system that runs from solar power. An alternative would be to have a bilge vent system with the fan mounted really high vaccuming out a tube that goes down to the bilge. The switch for the fan would also be mounted _really_ high so that it would be above any potentially explosive fumes from the bilge. Of course, your bilge pump auto-switch might still set it off while you are gone. I'd prefer that my boat not blow up at all, but if it does, I'd really like to not be standing in it at the time ;-) YMMV, Don W. wrote: Ari Glad to hear all ended well. My advice would be to get it out of the bilge. These things do no tlike getting wet. On my boat, the sniffer is just above the cabin sole in the face of one fo the settees. It is wired to bypass the master switch but is not always on. It has its own switch right next to the master switch. Procedure is to turn on the sniffer first. It will beep while it warms up (10 - 20 seconds) and then go silent once its warmed up and no gas is detected. I like this setup as it tests the sniffer every time you get on the boat. I spent the first season with this boat diligently turning on the sniffer and being happy at "silence" every time. Next spring I found out that the sniffer had been disconnected the whole previous season. Matt |
#12
![]() |
|||
|
|||
![]()
Very good stuff quoted below. Listen to Larry.
Now if the boat manufacturers would only build their systems this way. Larry W4CSC wrote: Marley wrote in : No fuse? Of course not! Boat installations of small-wired electronics is hardly ever fused at a safe level for the size of the wiring involved. It's wired to that 15 or 20A cheap thermal breaker that also drives the cabin lights, those tiny wires to the compass light, #22 wire to the GPS and those #22 wires to those GOD AWFUL little plastic Hella fans with NO INTAKE GUARDS in the cabin! You want us to put in a LITTLE FUSE PANEL to protect all those little wires?! What a concept! I'm confused about the remarks of the STUPID bilge pump switch. The bilge was full of water or smoke from the burning wiring?? Or did the stupidity of the bilge pump actually having an OFF position submerge this gas sensor, causing it to short out?? The CORRECT wiring procedure for the bilge pumps, ALL the bilge pumps, is a separate circuit STRAIGHT to the battery banks for each bilge pump. + battery with fuse within 6" of battery terminal (inline ok) to float switch to bilge pump to - battery terminal. If you so desire, the float switch may have a manual override switch in parallel with it in case it gets clogged or disabled, a good use for this stupid bilge pump switch. The fuse rating of EACH bilge pump would be protecting the SMALLEST wires, those little damned things to the plastic floatswitch or pump motor, in the circuit. I like to run the bilge pump under a load (pumping water unobstructed) while I measure its current. If it draws 1.3A under load, I want the next-higher-size fuse of twice that current ONLY IF THE WIRES CAN HANDLE IT. If the bilge pump motor becomes stalled with trash, I want the fuse to blow....instead of the bilge pump motor to just sit stalled and fry, possibly melting or catching fire. The bilge pump draws a lot of current starting under load, so use slow-blow fuses to prevent nuisance blows, rendering it useless. I find a STALLED Rule pump draws plenty more current to blow a double-the-normal-current fuse to save the pump. If it shorts, the fuse blows. If it stalls, the fuse blows saving the pump for a cleanout. No fire, no smoke...safe. Because EACH bilge pump has its OWN circuit/floatswitch/fuse, blowing one fuse doesn't disable all the pumps at once. Life goes on. There is the neatest little piezoelectric nag alarm at Radio Shack. It's a round, black plastic, 12V, nauseatingly antagonizing, pulsating beeper noise maker. Mount it through the plastic somewhere in the cockpit that will aggravate any sleepers below, plus anyone walking by on the dock. Connect this alarm (ours also has a bright red pilot light in parallel with it with a little sign saying what it means)....Connect this alarm/light combo ACROSS the fuse! + side of the beeper to the battery side of the fuse....- side of the beeper to the floatswitch side of the fuse. It will not beep or light UNTIL THE FUSE BLOWS, alarming you that that something is wrong with THAT bilge pump. Compared to a sunken ketch, cost of this little beeper alarm is MINIMAL! There...now NOONE can turn off the bilge pumps unless they unplug the fuse manually. The fuse protect the circuit from losing its "magic smoke" which makes all electrical/electronic gadgets run. It even protects the bilge pump from the trash that got in and locked the pump up so it won't fry the pump motor! When the trash...or a short....or a bad (shorted only) motor blows the fuse, the alarm sounds that something is wrong with THIS bilge pump, making troubleshooting at our earliest possible moment happen...before the water comes up over the teak and holly. Much better! Add another float switch on another separate, straight-to-battery-like-the- bilge-pump circuit. This float switch is 6" higher than the one that turns on the pump and should NEVER activate. If it does, it powers a Radio Shack alarm system 130db reentrant horn alarm that looks like a PA speaker up on the mast pointed down the dock so NOONE SLEEPS AS YOUR BOAT SINKS! As it has no OFF switch, they'll have to call you IMMEDIATELY to shut the damned thing up before the boat sinks.....(c; Flooding in the bilge is never funny! Please REWIRE every small electrical and electronic load in this boat in as many separate little fuse panels as is necessary so that each small load has its OWN properly-fused circuit. Hook the fuse panels to the breaker panel in the boat with wire appropriate to the size of the breaker. 20A breaker, use #12 or #10. 15A breaker, use #12 or #14....no smaller. Glowing wires like you've already witnessed can burn that plastic/epoxy beauty right to the waterline! |
#13
![]() |
|||
|
|||
![]()
Don W wrote in
: Very good stuff quoted below. Listen to Larry. Now if the boat manufacturers would only build their systems this way. The only way to make that happen is if someone, like CG or FTC FORCES them to make it happen. I always get a kick out of the "AYBC Standards"...or course, controlled by the MANUFACTURERS. Why does the FTC get so heated up about a little kid's car seat, for the Ford Exploder which flips over automatically.....when they could care less about the BOAT the kid slept in last night?? |
#14
![]() |
|||
|
|||
![]()
Don
I appreciate the scenario you describe. My on/off switch for the sniffer is located in a sail locker accessible only form the cockpit and is always turned on before anything else. It is located higher than the bottom of the companionway which is is no way air tight. The cocckpit drain exits the transom above the waterline. There are no guarantees in life but the system as it currently stands is good for most scenarios. Cheers Matt |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Propane refrigeration? | Boat Building | |||
Propane valves | Boat Building | |||
Propane valves | Cruising | |||
propane stoves | Cruising | |||
Copper Tubing in Propane System | Cruising |