Home |
Search |
Today's Posts |
|
#1
|
|||
|
|||
To many pumps!!!
On Fri, 08 Aug 2003 08:47:38 -0400, Glenn Ashmore
wrote: Damage significant enough to wipe out the entire pump platform would damage the hull so much that no pump could save the boat but I forgot to mention a 2000gph Rule forward, a 3700gph aft and an Edson manual under the cockpit. Oh yea, and then there is the 5300 gph 110V submersible with 50' of 2" discharge hose back in the lazerette for last ditch efforts. Like I said, to d**ned many pumps! Who was it that said there was no bilge pump quite as good as a scared man with a bucket? (You sure have a lot of pumps.) - Rick -- "Ignorant voracity -- a wingless vulture -- can soar only into the depths of ignominy." Patrick O'Brian |
#2
|
|||
|
|||
To many pumps!!!
Glenn Ashmore wrote:
snip ... and a grey water pump. snip Glenn -- Can't help with your question, but I have one of my own. I read your web site, so I understand (I think) how you have your grey water pump plumbed, but not why. Minimize the throughhulls? Something else? dave |
#3
|
|||
|
|||
To many pumps!!!
Dave Skolnick wrote: Can't help with your question, but I have one of my own. I read your web site, so I understand (I think) how you have your grey water pump plumbed, but not why. Minimize the throughhulls? Something else? Primarily to minimize through hulls and keep them out of the area forward of the keel where the most slamming can occur. Also, the galley arangement required that the sink be against the side where it may be below the waterline at a large angle of heel. That meant a sump and pump or religiously closing a throughhull every time. If the sump is going to be there for the sink it is logical to plumb everything else to it. Oh! Yea again. There is one more small booster pump in the forward head shower sump. -- Glenn Ashmore I'm building a 45' cutter in strip/composite. Watch my progress (or lack there of) at: http://www.rutuonline.com Shameless Commercial Division: http://www.spade-anchor-us.com |
#4
|
|||
|
|||
To many pumps!!!
more time sailing less time pumping, you'll go blind.
"Glenn Ashmore" wrote in message ... Having searched for hours for nonfunctioning pumps on deliveries I decided to put all my pumps on one centrally located platform under the salon sole. There are two fresh water pumps, one salt water wash down pump, one air conditioner cooling water pump, one fuel transfer pump, one Jabsco Sea Gulp bilge pump and a grey water pump. Only the waste pump, high pressure anchor sprayer and oil change pump are off the platform. Now I have to add a booster pump for the watermaker pump. Has anyone ever used the washdown pump as a watermaker boost pump? -- Glenn Ashmore I'm building a 45' cutter in strip/composite. Watch my progress (or lack there of) at: http://www.rutuonline.com Shameless Commercial Division: http://www.spade-anchor-us.com |
#5
|
|||
|
|||
To many pumps!!!
Glenn Ashmore wrote: ... Has anyone ever used the washdown pump as a watermaker boost pump? Jim Woodward wrote: As you certainly know, broadly there are two classes of pumps, high pressure / low volume and low pressure / high volume. I agree, although the distinction between positive displacement & nonPD is important for several reasons. Most booster pumps are non positive displacement so that they don't overpressurize the inlet side of the main pump casing. They can also supply positive flow over a wider pressure range, such as delivery to several subsystems. Another nice thing about non positive dispalacement pumps is that they can have flow through them when not running, and can readily be primed from either side. The former is good for water pressure, washdown and fire while the latter are used for bilge and sump applications. The best example of this difference is the Jabsco diaphragm pumps, where you can buy the same motor and frame driving different belt pulleys and diaphragms -- a single spare motor can back up both your freshwater and sump pumps.... Now I suspect the watermaker doesn't care much about pressure (there are so many variations today that I can't say for sure) and might even be upset if you had too much, but it does want a certain volume and minimum air. So, offhand, I'd suggest the AC cooling water pump rather than the washdown pump. Agreed, with the caveat that the AC cooling pump might be alternating current whereas Glenn might want to run his watermaker on 12V DC. But, you have a better way to make the choice -- look at the specs on the manufacturer recommended watermaker booster pump and then pick the pump you have that is closest. Too logical here. Aren't you even going to call anybody names?!? Fresh Breezes- Doug King |
#6
|
|||
|
|||
To many pumps!!!
Caught oversimplifying. Two demerits. Doug is right, of course,
although in my defense I will point out that the Air Con pump is almost certainly centrifugal (and, hence, non-PD) while the washdown could be either, so my suggestion is OK. Of course, in your praise of non-PD pumps, you don't mention that they are unholy nuisances, prone to lose their prime at the slightest provocation -- I remember surfing in the Southern trades from the Galapagos to the Marquesas, a lot of air under the boat and the reefer going down every five minutes because its pump didn't like air. Changing course to pamper a pump isn't my idea of ideal. Fortunately the pump was happy to run dry, but I would have traded it for a diaphragm pump of sufficent capacity in a second. (Or why Fintry has pressurized seawater available in volume from any of three sea chests -- I love the conservatism of the Royal Navy, but that's another story). Rutuonline doesn't tell us which supply he's running the watermaker from, so you may be right there. As for, "Too logical here. Aren't you even going to call anybody names?!?", I am the voice of reason -- I don't ever call people names, even when they're flaming something-or-others (which, let there be no mistake, does not apply to Glenn or Doug). Jim Woodward www.mvfintry.com DSK wrote in message ... Glenn Ashmore wrote: ... Has anyone ever used the washdown pump as a watermaker boost pump? Jim Woodward wrote: As you certainly know, broadly there are two classes of pumps, high pressure / low volume and low pressure / high volume. I agree, although the distinction between positive displacement & nonPD is important for several reasons. Most booster pumps are non positive displacement so that they don't overpressurize the inlet side of the main pump casing. They can also supply positive flow over a wider pressure range, such as delivery to several subsystems. Another nice thing about non positive dispalacement pumps is that they can have flow through them when not running, and can readily be primed from either side. The former is good for water pressure, washdown and fire while the latter are used for bilge and sump applications. The best example of this difference is the Jabsco diaphragm pumps, where you can buy the same motor and frame driving different belt pulleys and diaphragms -- a single spare motor can back up both your freshwater and sump pumps.... Now I suspect the watermaker doesn't care much about pressure (there are so many variations today that I can't say for sure) and might even be upset if you had too much, but it does want a certain volume and minimum air. So, offhand, I'd suggest the AC cooling water pump rather than the washdown pump. Agreed, with the caveat that the AC cooling pump might be alternating current whereas Glenn might want to run his watermaker on 12V DC. But, you have a better way to make the choice -- look at the specs on the manufacturer recommended watermaker booster pump and then pick the pump you have that is closest. Too logical here. Aren't you even going to call anybody names?!? Fresh Breezes- Doug King |
#7
|
|||
|
|||
To many pumps!!!
Now *THAT'S* what I call a prime throwaway line - or two....
I remember surfing .... Brian [envy, envy] Whatcott Altus OK On 13 Aug 2003 15:11:30 -0700, (Jim Woodward) wrote: Caught oversimplifying. Two demerits. /// -- I remember surfing in the Southern trades from the Galapagos to the Marquesas, a lot of air under the boat and the reefer going down every five minutes because its pump didn't like air. Changing course to pamper a pump isn't my idea of ideal. /// Jim Woodward www.mvfintry.com |
#8
|
|||
|
|||
Fintry's sea chests
"Jim Woodward" wrote in message m...
SNIP (Or why Fintry has pressurized seawater available in volume from any of three sea chests -- I love the conservatism of the Royal Navy, but that's another story). Jim, I've been mulling over the merits of sea chests recently. Could you please tell me a little more about Fintry's sea chests. In particular, where are the openings in the hull, how large are the openings, and is there any clever shaping to the hull openings to minimise drag and/or increase water flow into them? I'm also interested to hear about any other aspects of the sea chest arangement that you think might be of interest. I think my design philosophy probably exhibits much of the "conservatism of the Royal Navy" so I'd love to know in more detail what they did. Thanks in advance, Julian. |
#9
|
|||
|
|||
To many pumps!!!
This is in response to an e-mail from Julian. The return address on
his e-mail is , hence the reply here. ----- Original Message ----- From: "Julian" To: Sent: Thursday, August 14, 2003 10:08 AM Subject: Fintry's sea chests Jim, I've been mulling over the merits of sea chests recently. Could you please tell me a little more about Fintry's sea chests. In particular, where are the openings in the hull, how large are the openings, and is there any clever shaping to the hull openings to minimise drag and/or increase water flow into them? I'm also interested to hear about any other aspects of the sea chest arangement that you think might be of interest. I think my design philosophy probably exhibits much of the "conservatism of the Royal Navy" so I'd love to know in more detail what they did. Thanks in advance, Julian Julian: If you go to our web site, you'll find a piping diagram: http://www.mvfintry.com/pix/piping800.png and lines drawing: http://www.mvfintry.com/pix/flines800.png If you're interested, I can send you bigger versions (ie, more legible) of either -- just say how big is OK. The originals are in AutoCAD, if any of those formats are helpful. The sea chests are at frame 8 and 17 (of 45 total, 20" spacing), so they are well aft of midships, but they are also well down under the hull, where there is little deadrise. This is a disadvantage when she is in very shallow water or sitting in a mud berth. Her sister, Amazon Hope (see link on site), which is way up the Amazon in Peru, has recently been modified to avoid this problem. (The drawings at the bottom of http://www.mvfintry.com/details.htm all show frame locations). The chests are just steel boxes welded to the inside of the hull, with grating holes in the hull plating -- no special shaping at all. They're maybe a foot square and 6" high and have two valves mounted on the top for seawater intake and weed clearance (if you look at the piping layout, valves M19, M20, and M21 allow you to inject pressure seawater into a seachest with the intake valve closed to blast away anything that might clog the chest. Obviously, this trick works only if you have more than one seachest.) On the intake side, there's a large (although not particularly fine) strainer with a valve on either side to isolate it for cleaning. All the piping is galvanized steel, which requires attention from time to time, but has the advantage that it won't burn and sink the boat in case of an engine room fire. The fundamental advantage of a sea chest system is minimum holes in the hull. On a smaller scale than Fintry, when we bought our Swan 57, Swee****er, she had ten seawater intakes (engine, genset, refrigeration, 3 air conditioners, 2 heads, washdown, watermaker) and ten intake seacocks. If you started flooding, you'd have to close ten seacocks, several of which were very difficult to reach, in order to eliminate a bad hose as the cause of the flooding. As part of the preparation for our circumnav, we put in one 2" seacock, and manifolded everything to it. On top of the seacock was a tee, with the manifold connected to the side and a pipe plug in the top (think of the tee on its side with the straight through part vertical). By closing the sea cock, removing the pipe plug, screwing in a three foot length of pipe (long enough to be above waterline), and opening the seacock, we could push a rod down through the pipe, the tee, the seacock, and the hull and clean the intake. All of this requires some care to get it big enough and to make sure that centrifugal pumps have a steady upward path so that air will move up and out even if the pump loses its prime. On Fintry that's easy -- the engine room is twenty feet square and nine feet high and things like air con that use centrifugal pumps can be racked well above the seachest. On Swee****er, it was much harder, as everything was fitted into fairly small spaces. You'd like the intake to be in a high pressure area on the hull (see your naval architect) and I'd probably put a clamshell aft of it to help things along unless I were racing. The clamshell should be clear of the rod-through-the-hull trick if you use it. Jim Woodward www.mvfintry.com |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Forum | |||
Mercruiser Power Steering Pumps?? | General | |||
Can a single 72 gal per hour fuel pump run two 392 cu inch motors? | General |