a Big Pump
On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch
wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. The leads will be rated for the load. What you'll generally run into on considerable wire lengths is a nominal increase in resistance. Are your leads 16awg? 14 awg would work. Where persons can get into trouble is going with smaller awg sizes. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service -------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access |
a Big Pump
On Thu, 17 Sep 2009 12:03:18 -0700 (PDT), Frogwatch
wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access When you think about it, that's really only a gallon/second. This is the one you really want: http://www.starmarinedepot.com/Rule+Bilge+Pump+8000+Automatic+Submersible.html I'm thinking about getting a couple of them for our trawler before we head down to the islands next winter. |
a Big Pump
On Sep 17, 2:03*pm, Frogwatch wrote:
On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access When you think about it, that's really only a gallon/second.- Hide quoted text - - Show quoted text - That is pretty good capacity. You can't pour it out of a milk jug that fast. come to think of it, you can't dump it out of a pitcher that fast. That's a lot of water! |
a Big Pump
On Sep 17, 3:24*pm, wrote:
On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. The pump will not work nearly as well when it's only getting 9 - 10 volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look at http://www.powerstream.com/Wire_Size.htm At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck! |
a Big Pump
On Sep 17, 4:32*pm, Jack wrote:
On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. |
a Big Pump
On Sep 17, 6:30*pm, Tim wrote:
On Sep 17, 4:32*pm, Jack wrote: On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. 10g, cheap insurance. Copper is cheap, lives expensive |
a Big Pump
On Sep 17, 6:30*pm, Tim wrote:
On Sep 17, 4:32*pm, Jack wrote: On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. When I built the Tolman, I found 00 gage fully tinned battery cable for $3.00/ft on ebay and I used about 36' total (18' of black and 18' of red). |
a Big Pump
On Thu, 17 Sep 2009 15:53:11 -0700 (PDT), Katie Ohara
wrote: On Sep 17, 6:30*pm, Tim wrote: On Sep 17, 4:32*pm, Jack wrote: On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. When I built the Tolman, I found 00 gage fully tinned battery cable for $3.00/ft on ebay and I used about 36' total (18' of black and 18' of red). Fully tinned or aluminum? Quite often persons will mistake tinned copper for aluminum and aluminum for tinned copper. Generally welding cable will have a straight copper construction. Too, the higher MCM, i.e. 2/0, building wires like THHN will often be of an aluminum construction. These are typical constructions though. There are non-standard constructions out there. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service -------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access |
a Big Pump
On Sep 17, 8:47*pm, wrote:
On Thu, 17 Sep 2009 15:53:11 -0700 (PDT), Katie Ohara wrote: On Sep 17, 6:30*pm, Tim wrote: On Sep 17, 4:32*pm, Jack wrote: On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it.. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. When I built the Tolman, I found 00 gage fully tinned battery cable for $3.00/ft on ebay and I used about 36' total (18' of black and 18' of red). Fully tinned or aluminum? *Quite often persons will mistake tinned copper for aluminum and aluminum for tinned copper. *Generally welding cable will have a straight copper construction. *Too, the higher MCM, i.e. 2/0, building wires like THHN will often be of an aluminum construction. *These are typical constructions though. *There are non-standard constructions out there. * -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access Really tinned, cut it, you see copper, it also solders well |
a Big Pump
On Sep 17, 8:47*pm, wrote:
On Thu, 17 Sep 2009 15:53:11 -0700 (PDT), Katie Ohara wrote: On Sep 17, 6:30*pm, Tim wrote: On Sep 17, 4:32*pm, Jack wrote: On Sep 17, 3:24*pm, wrote: On Thu, 17 Sep 2009 12:02:45 -0700 (PDT), Frogwatch wrote: On Sep 17, 2:24*pm, wrote: On Thu, 17 Sep 2009 09:33:19 -0700 (PDT), Frogwatch wrote: Bought a 3700 gph Rule pump for the Tolman just in case I take a lot of water. *My normal bilge pump is a 750 gph one. *I intend to find some smooth bore hose for it and some oversized wire to power it. Downside is, it was expensive and I will probably never use it.. *Might even get a dedicated battery for it. You should only have to match the wire guage of the leads on your pump for your wiring. -- Posted via NewsDemon.com - Premium Uncensored Newsgroup Service * * * * * * *-------http://www.NewsDemon.com------ Unlimited Access, Anonymous Accounts, Uncensored Broadband Access I will probably go up one wire guage due to the long run from the battery that will be on the floor of the bow. My reason for getting this pump is reading David Pascoes advice on the topic. You can go up a gauge; but, there's really no reason to do so. *The leads will be rated for the load. *What you'll generally run into on considerable wire lengths is a nominal increase in resistance. *Are your leads 16awg? *14 awg would work. *Where persons can get into trouble is going with smaller awg sizes. Your absolutely correct that going to a smaller wire size is what gets most people into trouble. *However, I wouldn't go with anything smaller than 12ga, and 10ga would be better. That pump is ratted at 15.5 amps @ 12vdc, and 20 amps @ 13.6vdc. Basing on a 25 foot *run or wire, and depending on how you come at it, the wire resistance of the smaller 14-16ga wire could have you dropping 3 - 4 volts down the wire. *The pump will not work nearly as well when it's only getting 9 - 10 *volts. At least with the 12 or 10ga wire, you're reducing the copper loss down to 1 - 2 volts, and the pump will thank you. Take a look athttp://www.powerstream.com/Wire_Size.htm*At the bottom of the page is a calculator that will let you plug in the voltage, current, length and wire size, and will tell you the copper loss and end voltage. Good luck!- Hide quoted text - - Show quoted text - I vote 10g. When I built the Tolman, I found 00 gage fully tinned battery cable for $3.00/ft on ebay and I used about 36' total (18' of black and 18' of red). Fully tinned or aluminum? *Quite often persons will mistake tinned copper for aluminum and aluminum for tinned copper. *Generally welding cable will have a straight copper construction. *Too, the higher MCM, i.e. 2/0, building wires like THHN will often be of an aluminum construction. *These are typical constructions though. *There are non-standard constructions out there. * True, but THHN is not spec'd to be used in a low-voltage boat wiring project. My undestanding is that it, by definition, is a copper wire that is rated for residential and commercial building, to be installed in conduit or raceways. There certainly is aluminum equivalent out there and lots of people use it to reduce cost, but it's not supposed to be designated THHN. Also is pretty inflexible. |
All times are GMT +1. The time now is 08:49 AM. |
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 BoatBanter.com