  #1   Report Post  
Comcast
 
Posts: n/a
Default Microwave problem with XPOWER 1000 Inverter

I just purchased a Tappan 550W microwave that consumes 850W. I
also purchased a Xantrex Xpower 1000W inverter (modified sine wave).
About 20% of the time, when I start the microwave, the light turns on,
the turn table starts to rotate, and just as the magnetron starts up,
the microwave shuts off. The microwave seems to have lost power since
the clock resets. The other 80% of the time, the microwave works fine.
Once it successfully starts up, it will run continuously without a
problem.

The inverter has a continuous rating of 1000W with a peek output of 2000W.
I can't imagine that the microwave ever uses this much power to start.
The fault light on the inverter does NOT come on.

I have 2 large deep cycle batteries connected in parallel. They are
in excellent condition and provide over 260AH. I have connected the
inverter directly to the batteries with 2 AWG battery wire that I
purchased at the auto store. Is there a problem with the microwave
or inverter? Should I buy a more powerful inverter?

Thanks
Brent




  #2   Report Post  
 
Posts: n/a
Default

We run a 1000W consumption microwave (600W output) on our 1000W
Statpower Inverter (sine wave). Had no trouble with either.
Lyn & Tony
S/V Ambrosia

  #3   Report Post  
Meindert Sprang
 
Posts: n/a
Default

"Comcast" wrote in message
...
I just purchased a Tappan 550W microwave that consumes 850W. I
also purchased a Xantrex Xpower 1000W inverter (modified sine wave).
About 20% of the time, when I start the microwave, the light turns on,
the turn table starts to rotate, and just as the magnetron starts up,
the microwave shuts off. The microwave seems to have lost power since
the clock resets. The other 80% of the time, the microwave works fine.
Once it successfully starts up, it will run continuously without a
problem.

The inverter has a continuous rating of 1000W with a peek output of 2000W.
I can't imagine that the microwave ever uses this much power to start.


The inrush current of a large transformer can be 5 to 25 times the nominal
current. And that is when fed with a sinewave current. With a modified
sineware (which is just a square wave which stays on 0-V for some time,
every cycle), the inrush current can be much higher.

Meindert


  #4   Report Post  
Jack Erbes
 
Posts: n/a
Default

Comcast wrote:

I just purchased a Tappan 550W microwave that consumes 850W. I
also purchased a Xantrex Xpower 1000W inverter (modified sine wave).

snip

snip Is there a problem with the microwave
or inverter? Should I buy a more powerful inverter?


Some types of electrical or electronic equipments do not work or do not
work well on modified sine wave inverters. If you look in your manual
or at the Xantrex web site, it will tell you what those are.

That may be your problem. If it is, a pure sine wave inverter will cure
it. Guess what? It may be time to throw another bucket full of money
into your "hole in the water". :)

Jack

--
Jack Erbes in Ellsworth, Maine, USA - jackerbes at adelphia dot net
(also receiving email at jacker at midmaine.com)
  #5   Report Post  
Neon John
 
Posts: n/a
Default

It sounds like the microwave is tripping off on undervoltage. I'd be
looking at my 12 volt connections, as that is the usual source of the
problem. Depending on the length of the run, that #2 wire may be a
bit small.

An easy test is to plug in a low wattage bulb to the inverter and
watch how much it dims as the magnetron comes up to speed. You might
also try running the system with the engine running (assuming a MH) or
a high power charger in place to see if the added voltage will help.

FWIW, I run a 600 watt microwave from a 1000 watt Vector inverter with
no problems at all. I chose a microwave with a mechanical timer so as
to avoid all those glitch problems.

John


On Wed, 23 Feb 2005 01:54:01 -0800, "Comcast"
wrote:

I just purchased a Tappan 550W microwave that consumes 850W. I
also purchased a Xantrex Xpower 1000W inverter (modified sine wave).
About 20% of the time, when I start the microwave, the light turns on,
the turn table starts to rotate, and just as the magnetron starts up,
the microwave shuts off. The microwave seems to have lost power since
the clock resets. The other 80% of the time, the microwave works fine.
Once it successfully starts up, it will run continuously without a
problem.

The inverter has a continuous rating of 1000W with a peek output of 2000W.
I can't imagine that the microwave ever uses this much power to start.
The fault light on the inverter does NOT come on.

I have 2 large deep cycle batteries connected in parallel. They are
in excellent condition and provide over 260AH. I have connected the
inverter directly to the batteries with 2 AWG battery wire that I
purchased at the auto store. Is there a problem with the microwave
or inverter? Should I buy a more powerful inverter?

Thanks
Brent




---
John De Armond

http://www.johngsbbq.com
http://neonjohn.blogspot.com -- NEW!
Cleveland, Occupied TN


  #7   Report Post  
 
Posts: n/a
Default

On Wed, 23 Feb 2005 19:37:56 GMT, Larry W4CSC wrote:

"Comcast" wrote in news:W5idnZlIFrFdz4HfRVn-
:

Is there a problem with the microwave
or inverter? Should I buy a more powerful inverter?

Thanks
Brent


No, you should buy a cheaper microwave! We paid $15 for the Samsung with
the windup timer on the front and NO ELECTRONICS to screw it up!

Microwaves with cheap, mechanical windup electric timers work just fine off
inverters....even the cheap 1KW Radio Shack screwed to Lionheart's bulkhead
with the custom miniature power switch at the nav table...


Our Samsung works off a single marine battery, but... it takes about
twice as long to heat stuff up and it chomps on the battery pretty
hard. When practical we use propane to heat food and beverages
instead.
  #8   Report Post  
Wayne.B
 
Posts: n/a
Default

On Wed, 23 Feb 2005 11:45:14 -0500, Neon John
wrote:

It sounds like the microwave is tripping off on undervoltage. I'd be
looking at my 12 volt connections, as that is the usual source of the
problem. Depending on the length of the run, that #2 wire may be a
bit small.


=============================

I agree that #2 wire is marginal at best. You are pulling well over
100 peak amps and voltage loss in the cable increases as the square of
current flow. I'd sugggest something like 2/0 cable both to the
inverter and for your battery parallel straps.

It is true however that some devices just refuse to run on modified
sine wave power. We had to try several different brands of electric
blankets before we found one that worked.

  #9   Report Post  
Larry W4CSC
 
Posts: n/a
Default

Wayne.B wrote in
:

It is true however that some devices just refuse to run on modified
sine wave power. We had to try several different brands of electric
blankets before we found one that worked.


Oh, Wayne. I just gotta hear all about your house battery banks and
charging system.

How many amp-hours are aboard to run electric blankets and the other loads
all night?

Thanks.....



(Nothing is funnier than a boater with a new 4KW inverter carrying his
electric heater down the dock with that knowing smile on his face....)


  #10   Report Post  
Neon John
 
Posts: n/a
Default

On Thu, 24 Feb 2005 11:46:01 GMT, Larry W4CSC wrote:

Wayne.B wrote in
:

It is true however that some devices just refuse to run on modified
sine wave power. We had to try several different brands of electric
blankets before we found one that worked.


Oh, Wayne. I just gotta hear all about your house battery banks and
charging system.

How many amp-hours are aboard to run electric blankets and the other loads
all night?


I just looked at the tag on my king-size electric blanket. It draws
200 watts. That'd be about 16.67 amps at full load from the battery.

Not many people would use a king size bed in an RV. More like a twin
or regular. I'd guesstimate the draw to be more in the 60 watt range
or 5 amps. This corresponds well to my 12 volt electric throw that I
use that draws 3.5 amps. Remember that these things are
thermostatically controlled so they don't run all the time. That
makes the actual situation better than it looks.

I have a couple of Group 29 batteries in my rig and have no problem
running the blanket, the furnace and other loads for a day at a time.
According to the E-meter, I'll typically use 80 ah per 24 hour period
in the winter.


(Nothing is funnier than a boater with a new 4KW inverter carrying his
electric heater down the dock with that knowing smile on his face....)


Yup. Old rule of thumb, a gallon of gas is about the energy
equivalent of about 1000 lbs of lead-acid batteries.

John
---
John De Armond

http://www.johngsbbq.com
http://neonjohn.blogspot.com -- NEW!
Cleveland, Occupied TN
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
microwave/inverter Brian Whatcott Cruising 11 December 26th 04 10:01 AM
??? about an inverter system Derek General 16 July 7th 04 12:24 PM
??? about an inverter system [email protected] Boat Building 9 July 7th 04 12:24 PM
??? about an inverter system [email protected] Cruising 9 July 7th 04 12:24 PM
Inverter in 2460 Regal? Michael Robison Cruising 10 May 21st 04 07:45 PM


All times are GMT +1. The time now is 10:35 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017