Home |
Search |
Today's Posts |
#8
![]() |
|||
|
|||
![]()
Doug,
Again thanks for the information. I wasn't aware of the difference, I guess that's something I'll have to be on the lookout for when I shop for a boat. Paul "Doug Dotson" wrote in message ... The difference I was referring to was in GFCI which is a strictly an AC device. The bimetal breakers are thermal breakers. Pretty much obsolete in the boating world. Magnetic breakers seem to be the norm now. I had a thermal breaker panel on my boat when I bought it. The whole panel would sometime get almost too hot to touch when loaded heavily. Doug s/v Callista "Paul Schilter" paulschilter@comcast,dot,net wrote in message ... Doug, Thanks for the correction, I was referring to AC breakers. Although I wasn't aware there are specific breakers for DC. In machine control we don't have breakers that are specific to DC or AC. 10 amps is 10 amps regardless if it's AC or DC. I believe the breakers I'm familiar with are bimetal in nature, if the amps pulled go over their rated value, the bimetal strip heats up to the point it trips the breaker. The bimetal strip is a bonded piece that has one type of metal on one side and a different type on the other. The metals have a different rate of expansion as it heats up from the current passing through it bends in an arc. If it bends far enough it trips the breaker. As now the current is stopped, the bimetal cools allowing the breaker to be reset. Paul "Doug Dotson" wrote in message ... I assumed that the dicussion was related to breakers commonly used on boats. ie Magnetic breakers these days. Breakers that aren't guaranteed to work more than once would be pretty useless. I think they are traditionally known as fuses ![]() are for AC. The T1 breaker that started this thread is for 12 VDC. Doug s/v Callista "Paul Schilter" paulschilter@comcast,dot,net wrote in message ... Doug, All circuit breakers are not designed to be used as switches. Actually they aren't guaranteed to work more than once, but I've know them to work many times after being tripped repeatedly. They do make circuit breakers that are intended to be used as a switch, I believe they have an "S" designation on the breaker. If I were replacing circuit breakers I'd get GFCI (ground fault circuit interrupter). They're a bit more but around the water it seems like a good investment. Paul "Doug Dotson" wrote in message ... Waste of switches. Breakers make fine switches. Don't know where Larry is coming from on this one (as usual). The problem with the T1 breaker is it is not idiot proof. If you hold the breaker in the on position it holds the circuit closed rather then interrupting again like a normal magnetic breaker will. I believe that the older thermal breakers always behaved this way but I'm not sure. In any case, only a moron would hold a breaker closed, but then again there seems to be an unlimited supply of morons on boats these days ![]() Doug s/v Callista "Rusty O" wrote in message hlink.net... Mine doesn't. All loads are switched or controlled by other than the circuit breakers. Rusty O |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Mercruiser Alpha 1 - 3.0 Liter Starter Circuit Problem | General | |||
Touring Bike recall | General | |||
Circuit Breaker Safety Recall | Electronics | |||
circuit breaker installation | Electronics | |||
AC/DC Circuit Breakers | Cruising |