Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #41   Report Post  
JAXAshby
 
Posts: n/a
Default Alternative power Refrigeration

the inertial mass

whore ace, wanna explain to us just what INinertial mass is? Or wanna try to
explain just what kind of mass there is that has no inertia?

[stay awake, people, if you can. whore ace is going to try to sound like an
11th grader]
  #42   Report Post  
Matt Colie
 
Posts: n/a
Default Alternative power Refrigeration

Jax,

I kind of hate to tell you this, but maintaining the liquid fill in the
generator (you called a burner pot?) is actually pretty simple. We
managed to blow that one away early in the program. With the correct
mixer - generator layout and connection it will function properly at
latteral loads to 1g (project design standard). Wouldn't that would be
close to a 45 deg heel? other thread

The last people that called me about this project a couple of years ago
bought consulting time that produced a spreadsheet that laid out all the
costs and benefits. They were looking at a system to include in
powerboats. Ventilation became a serious issue. That would still be an
issue in good boats. The potential to power the refrigation with
alternative power generation (solar, wind, towfish) were of no interest
to them. The fact that the unit could be run on waste heat from a
modified exhaust manifold did not get anything because the hours at
design load were not there (planing hull). The potential to fuel it
with diesel still did not win the game.

The COP is the game killer. The required ventiation is next. Never
mind that the system has not moving parts and can not wear out.

Matt Colie - See Prior Sigs



JAXAshby wrote:
matt, close but no cigar. the unit needs to be more or less vertical so that
the liquid drains all the way back to the burner. If the liquid does not get
back there they burner pot gets scorched and the unit is ruined.

but yes, a cigar regarding efficiency. gas absorbtion refrigerators are much
less efficient than compressor reefers, when comparing energy input vs cooling
capacity. One a boat, electricity is incredibly expensive to make per
kilowatt, and HUGELY expensive compared to the same kilowatt purchased as
propane.

A kilowatt of electricity produced on a boat can cost $2 to $5 dollars EACH,
while a gallon of propane (about 90,000 btu's, or about 30 kilowatts) goes for
maybe a couple bucks (? I can't remember how much I paid for 10# of propane
last summer, but it certainly was pocket change)


You people seem to have missed two things in the thermodynamics part of
your education.

A Servel Cycle (the identifier for water/hydrogen/ammonia abortion
refrigeration) requires both the persistance of two liquid/vapor seals
and a lot of vertical room.

The vertical height is required so the ammonia can get condensed and
then be run down into the evaporator by gravity.

The two sealing loops separate a: ammonia vapor from ammonia liquid and
hydrogen and b: water from hydrogen.

The "household" units - these include RV - do not have seals that work
well out of vertical. Seals for these have been designed that do just
fine at a considerable offset. If the seals get blow out, they will
re-establish themselves with a reasonable amount of running time.

A one time I was employed by a company that was in the process of
developing a refrigeration system that could used the exhaust heat of an
RV to be the motivating heat for the refrigeration (apart from the fact
that the system had real flexability issues as far as installaion) the
whole program went down in flames whent he bottom fell out of the RV
market during the original Arab Oil Embargo.

Another issue for sailors would be that the COP (co-efficient of
performance - sort of the effieciency) of Servel units was not as good
as an R12 or R22 unit.

Matt Colie


Horace Brownbag wrote:

On 04 Jul 2004 02:05:22 GMT, (JAXAshby) wrote:



The
real problem with absorption cycle refrigeration (gas refrigerators) is
that they must stay within 5 to 7 degrees of vertical.

not true. unless the vehicle is NOT moving side to side.


lateral forces mimic inclination.











  #46   Report Post  
Horace Brownbag
 
Posts: n/a
Default Alternative power Refrigeration

On Sun, 04 Jul 2004 22:31:17 -0400, Matt Colie
wrote:
snip
The COP is the game killer. The required ventiation is next. Never
mind that the system has not moving parts and can not wear out.


I hunted for years for a Servel for my rural home. I finally found
one, not ready to pay thousand or so bucks for a new one.

The damn thing was 50 years old. It looked new. I dropped it in.

My electric went down 20 bucks a month, and my propane went up 5...and
only on the quieter winter nights could I hear the flame going.... I
heated with wood; what did I care if the power went out? Which
doesn't mean anything except I thought it was cool.

It was not as fast to recover, not as spacious, nor was the interior
design up to today's standards, but built like a tank. I hated to
part with it.

  #47   Report Post  
JAXAshby
 
Posts: n/a
Default Alternative power Refrigeration

I kind of hate to tell you this, but maintaining the liquid fill in the
generator (you called a burner pot?) is actually pretty simple.


yup, I think I said that right from the start, as long as the boat is rocking
around a bit, but NOT in an RV parked off level more than a few degrees.

it will function properly at
latteral loads to 1g


more than 1 g actually. much more.

Wouldn't that would be
close to a 45 deg heel?


no. lateral loads and degree heel are not interchangeable terms in this issue.

The last people that called me about this project a couple of years ago
bought consulting time


ah, THAT proves you are knowledgeable, doesn't it. someone paid you money to
hear you talk.

They were looking at a system to include in
powerboats.


then they were wasiting their time. powerboats have excess power available
compared to the power needs of a reefer system.

Ventilation became a serious issue. That would still be an
issue in good boats.


nah, a propane reefer has such a tiny flame is hard to tell the unit is running
unless you hold your hand over the chimney for upwards of thirty seconds or
more.


  #48   Report Post  
JAXAshby
 
Posts: n/a
Default Alternative power Refrigeration

whore ace, don't use terms again you are not familiar with.

the inertial mass


whore ace, wanna explain to us just what INinertial mass is? Or wanna try

to
explain just what kind of mass there is that has no inertia?

[stay awake, people, if you can. whore ace is going to try to sound like an
11th grader]



Ok, I'll give it a shot....

Inertial mass is having the rug is pulled out from under you.

Inertial mass is the object tending to remain at rest...which is
contrasted with the moment, or the framework of the referent,
i.e.....oh, look, everyone has dozed off.









  #49   Report Post  
JAXAshby
 
Posts: n/a
Default Alternative power Refrigeration

whore ace, the more you open your mouth the more you show yourself to have an
empty skull.

whore ace, would you mind very much explaining to the ng just how a dinner
plate is like the pot of a closed gas absorbtion reefer system?

[stay awake people, if you can. whore ace is going to try to sound like an
11th grader]

The plate will do it job if it's not tipped, or moved
laterally, without tipping, faster than the inertial mass of the fluid
on the plate


The dinner plate is like the bottom of an evaporator; just like it's a
North Dakota slough.

...for someone who knows I have nothing to add, you sure are curious.








  #50   Report Post  
JAXAshby
 
Posts: n/a
Default Alternative power Refrigeration

whore ace, go back to listening to the propane flame crackling away late at
night on your 50 year old reefer.


whore ace, you are comparing watermelon on dinner plates to gas absorbtion
refrigerators.

why? Because you think you understand dinner plates?

go back to study hall. lunch is not for another 45 minutes.


hore ace, here is the stupid statement you made which shows to one and all
you
don't have a clew what you are talking about in regard to gas absorbtion
refrigeration and were just picking junk out of the air just to say
something
hoping the rest of us here might notice you. you act like a high school
sophomore whose voice has not yet changed. go away and come back when you
shave at least twice a week.

lateral forces mimic inclination.

Well, let me struggle through this as best I can't and hope my voice
doesn't crack.

You've just eaten a nice thick cool slice of watermelon. The plate is
full of juice. The plate will do it job if it's not tipped, or moved
laterally, without tipping, faster than the inertial mass of the fluid
on the plate..oops, there goes the watermelon juice....

No juice in the evaporator; no cool watermelon.

...oh, sorry, gotta go, my mom wants me to clean up my room.


Why, I believe I was... Thanks for noticing. Your intelligence is
only exceeded by your charm....








Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
12V refrigeration Skip Gundlach Boat Building 19 July 4th 04 01:18 AM
Refrigeration Cold Plate Temperature Differential GeoffSchultz Cruising 0 January 20th 04 12:44 AM
Refrigeration Hunter 35.5 install Ron Cruising 5 October 25th 03 10:08 PM


All times are GMT +1. The time now is 11:32 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017