Default Water tank vent overboard or bilge

Comments below.

Doug
s/v Callista

"Peggie Hall" wrote in message
...
Doug Dotson wrote:
Not sure how grease etc is going to leap out of the galley sink into
the vent


Prob'ly won't if you never fill the sink to wash dishes or allow any
dirty dishwater to go down the drain.


You don't understand how the vents are installed. They are not
plumbed into the drains. Just empty into the basins.

Our tanks are vented into the head sinks via a spout in
each. Easy to see when the tanks are full when filling...


As long as you're in the head while they're filling... or there's no
plug in the sink if you aren't.


I suppose that not leaving a plug in the drains is a requirement.
Not really a problem.

I think the vent should go out the hull. But hey...they're YOUR boats,
so whatever floats 'em for YOU is fine with me.


To be really safe, put them in the cockit. That way they will drain
out the scuppers and not be so prone to taking in sal****er. Another
option is to put them up the mast a bit. I know someone that did this.
Overflow will go out the fill rather than out the vent. Problem solved
forever.


--
Peggie
----------
Peggie Hall
Specializing in marine sanitation since 1987
Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and
Other Sources of Aggravation and Odor"
http://69.20.93.241/store/customer/p...40&cat=&page=1



  #2   Report Post  
Glenn Ashmore
 
Posts: n/a
Default Water tank vent overboard or bilge



Doug Dotson wrote:

To be really safe, put them in the cockit. That way they will drain
out the scuppers and not be so prone to taking in sal****er. Another
option is to put them up the mast a bit. I know someone that did this.
Overflow will go out the fill rather than out the vent. Problem solved
forever.


I set my water tank vents on the outside of the cockpit coaming just
down hill from the deck fill. When the tank is full water flows across
the side deck and out the scupper. You do have to be careful to locate
the vents so that the overflow will not flow back into the deck fill.

Chartered a boat once that had the vent lines run up inside the
stantions with a vent hole just under the top lifeline. Worked great
but if you were holding the hose when the tank overflowed it would spray
you in the face. :-)


--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com

  #3   Report Post  
hanz
 
Posts: n/a
Default Water tank vent overboard or bilge

Air vents for the water tanks are just for venting air (to allow air to
enter when water is being pumped out and to allow air to escape when
filling the tank) not for water escape. If you are using them for water
escape, be very careful. WHen filling the tanks you better NOT have too
much pressure. Even .5 psi can put a lot of pressure on the tops of
tanks - 2'x 5'lid = 24"x 60" = 1440 sq in x .5= 720 pound of pressure,
enough to cause the lid to buckle and separate.

When filling, we always remove the input vent on the top of our tanks
and 'watch' the water filling. Even the exhaust vent in the tanks can
cause pressure.


Hanz

Glenn Ashmore wrote:


Doug Dotson wrote:

To be really safe, put them in the cockit. That way they will drain
out the scuppers and not be so prone to taking in sal****er. Another
option is to put them up the mast a bit. I know someone that did this.
Overflow will go out the fill rather than out the vent. Problem solved
forever.



I set my water tank vents on the outside of the cockpit coaming just
down hill from the deck fill. When the tank is full water flows across
the side deck and out the scupper. You do have to be careful to locate
the vents so that the overflow will not flow back into the deck fill.

Chartered a boat once that had the vent lines run up inside the
stantions with a vent hole just under the top lifeline. Worked great
but if you were holding the hose when the tank overflowed it would spray
you in the face. :-)



  #4   Report Post  
Doug Dotson
 
Posts: n/a
Default Water tank vent overboard or bilge

Not likely that too much pressure can build in the vent while
overflowing out the fill.

Doug
s/v Callista

"hanz" wrote in message
...
Air vents for the water tanks are just for venting air (to allow air to
enter when water is being pumped out and to allow air to escape when
filling the tank) not for water escape. If you are using them for water
escape, be very careful. WHen filling the tanks you better NOT have too
much pressure. Even .5 psi can put a lot of pressure on the tops of
tanks - 2'x 5'lid = 24"x 60" = 1440 sq in x .5= 720 pound of pressure,
enough to cause the lid to buckle and separate.

When filling, we always remove the input vent on the top of our tanks
and 'watch' the water filling. Even the exhaust vent in the tanks can
cause pressure.


Hanz

Glenn Ashmore wrote:


Doug Dotson wrote:

To be really safe, put them in the cockit. That way they will drain
out the scuppers and not be so prone to taking in sal****er. Another
option is to put them up the mast a bit. I know someone that did this.
Overflow will go out the fill rather than out the vent. Problem solved
forever.



I set my water tank vents on the outside of the cockpit coaming just
down hill from the deck fill. When the tank is full water flows across
the side deck and out the scupper. You do have to be careful to locate
the vents so that the overflow will not flow back into the deck fill.

Chartered a boat once that had the vent lines run up inside the
stantions with a vent hole just under the top lifeline. Worked great
but if you were holding the hose when the tank overflowed it would spray
you in the face. :-)





  #5   Report Post  
Dick Locke
 
Posts: n/a
Default Water tank vent overboard or bilge

On Sat, 26 Jun 2004 10:03:56 -0400, hanz
wrote:

WHen filling the tanks you better NOT have too
much pressure. Even .5 psi can put a lot of pressure on the tops of
tanks - 2'x 5'lid = 24"x 60" = 1440 sq in x .5= 720 pound of pressure,
enough to cause the lid to buckle and separate.


I was thinking of writing along this line because I had that issue
with my fuel tanks. It's easy to get a lot of pressure. Say a water
tank vent outlet (or filler cap) is 6 feet above the tank. By the time
water comes out the vent or filler cap you have about 1/5 atmosphere
or 3 psi in the tank. Fuel is similar, probably 75% of that pressure.
My tank vents are fairly high up a coaming on a center cockpit and the
fuel tanks are under the sole. There's 7-8 feet of head. My tanks
oozed around some fittings that were not used to pressure and around
an inspection port that wasn't really adequately gasketed.



Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Angle of prop shaft - theoretical question. Gary Warner General 103 June 18th 04 05:32 AM
Water in the Bilge Ernie General 20 April 16th 04 04:20 AM
Ideas on Motor/Tranny issues Mark Davis General 4 February 10th 04 03:26 AM
Where to find ramp stories? designo General 15 December 9th 03 08:57 PM
Clogged waste tank vent RG General 0 September 15th 03 10:50 AM


All times are GMT +1. The time now is 12:10 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017