Home |
Search |
Today's Posts |
#21
![]() |
|||
|
|||
![]() "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip The other possibility is that due to a deeper discharge of one battery, it takes longer for the total voltage to reach the point where the charger goes from bulk to float. So while for the more empty battery the charge is still ok (bulk), the other one still gets the full bulk current too while it should receive a float charge. Deeper discharge of some cells in the string will not, of itself, mean that the charge takes longer. The _difference_ doesn't matter. The amount of charge required controls the charge time. Whether OP is running his radio off one battery or both makes no difference to the ah used, and therfore no difference to the charge time (except, of course, that if he uses a converter he will be consuming more ah for a given usage than if he uses just one battery). Go and read my last post again. The charge doesn't magically share itself according to need between the two batteries connected in series. Instead, the charging current supplies equal charge to both batteries. If one becomes fully charged before the other, then the only way that the partially charged battery can get more charge is by overcharging the other. That overcharge is "energy" which cannot be stored in the battery, but has to go somewhere, and that somewhere is either/or elctrolysing the battery water to oxygen and hydrogen, and heat. If the discrepancy is small, it probably doesn't matter, but if not, then it certainly does. |
#22
![]() |
|||
|
|||
![]()
Forget for a moment the issue of connecting a 12 volt load
to a 24 volt system. Consider only the problem of properly charging two 12 volt batteries in series with a single 24 volt charger. My understanding is that unless the two batteries are identical (goes way beyond same make or capacity) they will not be charged to the same voltage. Two electrically non-identical batteries will have different internal resistances (by assumption)and thus charge to different voltages. As I mentioned in an earlier post, Ample Power shares this understanding and offers a 24 volt charger that is in reality two 12 volt chargers, one connected to each of the two 12 volt batteries (which are in series, of course). If my understanding is incorrect, that would mean that a 12 volt marine battery and 8 AAA's in series would all be properly charged by a 24 volt charger (with current limited so as not to destroy the AAA's). An attempted reductio ad absurdum. My point is simply that with a real-world installation of two 12 volt batteries in series, the two batteries will probably measure different voltages. The greater the differences between the batteries, the greater the potential problem (no pun). Without knowing the internal resistances, etc. of the two batteries, it is not possible to know the precise effect of placing a different load on one of the batteries. Doing so would effectively place the added load resistance in parallel with the internal resistance of the affected battery. That could make the two batteries either more or less alike, depending on the values involved. All of this is hand-waving, of course, because a battery's internal resistance is really not a constant, but a function of the battery's chemistry, state-of-charge, etc. It is a non-linear resistance, in that it varies with current. I don't believe we miss the mark here by ignoring these factors, however. Regards, Chuck Pete Styles wrote: "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip The other possibility is that due to a deeper discharge of one battery, it takes longer for the total voltage to reach the point where the charger goes from bulk to float. So while for the more empty battery the charge is still ok (bulk), the other one still gets the full bulk current too while it should receive a float charge. Deeper discharge of some cells in the string will not, of itself, mean that the charge takes longer. The _difference_ doesn't matter. The amount of charge required controls the charge time. Whether OP is running his radio off one battery or both makes no difference to the ah used, and therfore no difference to the charge time (except, of course, that if he uses a converter he will be consuming more ah for a given usage than if he uses just one battery). Go and read my last post again. The charge doesn't magically share itself according to need between the two batteries connected in series. Instead, the charging current supplies equal charge to both batteries. If one becomes fully charged before the other, then the only way that the partially charged battery can get more charge is by overcharging the other. That overcharge is "energy" which cannot be stored in the battery, but has to go somewhere, and that somewhere is either/or elctrolysing the battery water to oxygen and hydrogen, and heat. If the discrepancy is small, it probably doesn't matter, but if not, then it certainly does. |
#23
![]() |
|||
|
|||
![]()
On Sat, 16 Apr 2005 10:12:46 GMT, "Pete Styles"
wrote: "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip The other possibility is that due to a deeper discharge of one battery, it takes longer for the total voltage to reach the point where the charger goes from bulk to float. So while for the more empty battery the charge is still ok (bulk), the other one still gets the full bulk current too while it should receive a float charge. Deeper discharge of some cells in the string will not, of itself, mean that the charge takes longer. The _difference_ doesn't matter. The amount of charge required controls the charge time. Whether OP is running his radio off one battery or both makes no difference to the ah used, and therfore no difference to the charge time (except, of course, that if he uses a converter he will be consuming more ah for a given usage than if he uses just one battery). Go and read my last post again. The charge doesn't magically share itself according to need between the two batteries connected in series. Instead, the charging current supplies equal charge to both batteries. If one becomes fully charged before the other, then the only way that the partially charged battery can get more charge is by overcharging the other. That overcharge is "energy" which cannot be stored in the battery, but has to go somewhere, and that somewhere is either/or elctrolysing the battery water to oxygen and hydrogen, and heat. If the discrepancy is small, it probably doesn't matter, but if not, then it certainly does. Pete is right on the mark. Reread his prior post. Also go back and read Bruce's post on the subject. It is bad news to tap a battery bank. You can get away with it for a time but it will shorten battery life because the two batteries do not get charged equally. As Pete says, "in order to get the battery that is used the most charged fully you must overcharge the other". There is no way around that. Overcharging a battery not only cause water loss but it can warp the plates in the battery among other things. Overcharging is the biggest killer of batteries. Just ask anyone that still uses a feroresonant charger. They will tell you batteries last only a couple of years. Do it properly and use the inverter. regards Gary |
#24
![]() |
|||
|
|||
![]() "Gary Schafer" wrote in message ... On Sat, 16 Apr 2005 10:12:46 GMT, "Pete Styles" wrote: "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip The other possibility is that due to a deeper discharge of one battery, it takes longer for the total voltage to reach the point where the charger goes from bulk to float. So while for the more empty battery the charge is still ok (bulk), the other one still gets the full bulk current too while it should receive a float charge. Deeper discharge of some cells in the string will not, of itself, mean that the charge takes longer. The _difference_ doesn't matter. The amount of charge required controls the charge time. Whether OP is running his radio off one battery or both makes no difference to the ah used, and therfore no difference to the charge time (except, of course, that if he uses a converter he will be consuming more ah for a given usage than if he uses just one battery). Go and read my last post again. The charge doesn't magically share itself according to need between the two batteries connected in series. Instead, the charging current supplies equal charge to both batteries. If one becomes fully charged before the other, then the only way that the partially charged battery can get more charge is by overcharging the other. That overcharge is "energy" which cannot be stored in the battery, but has to go somewhere, and that somewhere is either/or elctrolysing the battery water to oxygen and hydrogen, and heat. If the discrepancy is small, it probably doesn't matter, but if not, then it certainly does. Pete is right on the mark. Reread his prior post. Also go back and read Bruce's post on the subject. It is bad news to tap a battery bank. You can get away with it for a time but it will shorten battery life because the two batteries do not get charged equally. As Pete says, "in order to get the battery that is used the most charged fully you must overcharge the other". There is no way around that. Overcharging a battery not only cause water loss but it can warp the plates in the battery among other things. Overcharging is the biggest killer of batteries. Just ask anyone that still uses a feroresonant charger. They will tell you batteries last only a couple of years. Do it properly and use the inverter. regards Gary I disagree. Two 12v batteries in series to make a 24v battery will self-level with respect to charge. They will self level even if one is tapped to run a VHF. No harm will come to either battery. Voltage can be likened to pressure. I hope this helps. CN |
#25
![]() |
|||
|
|||
![]() "Capt. Neal®" wrote in message ... "Gary Schafer" wrote in message ... On Sat, 16 Apr 2005 10:12:46 GMT, "Pete Styles" wrote: "James Hahn" wrote in message news ![]() ... snip The other possibility is that due to a deeper discharge of one battery, it takes longer for the total voltage to reach the point where the charger goes from bulk to float. So while for the more empty battery the charge is still ok (bulk), the other one still gets the full bulk current too while it should receive a float charge. Deeper discharge of some cells in the string will not, of itself, mean that the charge takes longer. The _difference_ doesn't matter. The amount of charge required controls the charge time. Whether OP is running his radio off one battery or both makes no difference to the ah used, and therfore no difference to the charge time (except, of course, that if he uses a converter he will be consuming more ah for a given usage than if he uses just one battery). Go and read my last post again. The charge doesn't magically share itself according to need between the two batteries connected in series. Instead, the charging current supplies equal charge to both batteries. If one becomes fully charged before the other, then the only way that the partially charged battery can get more charge is by overcharging the other. That overcharge is "energy" which cannot be stored in the battery, but has to go somewhere, and that somewhere is either/or elctrolysing the battery water to oxygen and hydrogen, and heat. If the discrepancy is small, it probably doesn't matter, but if not, then it certainly does. Pete is right on the mark. Reread his prior post. Also go back and read Bruce's post on the subject. It is bad news to tap a battery bank. You can get away with it for a time but it will shorten battery life because the two batteries do not get charged equally. As Pete says, "in order to get the battery that is used the most charged fully you must overcharge the other". There is no way around that. Overcharging a battery not only cause water loss but it can warp the plates in the battery among other things. Overcharging is the biggest killer of batteries. Just ask anyone that still uses a feroresonant charger. They will tell you batteries last only a couple of years. Do it properly and use the inverter. regards Gary I disagree. Two 12v batteries in series to make a 24v battery will self-level with respect to charge. They will self level even if one is tapped to run a VHF. No harm will come to either battery. Voltage can be likened to pressure. I hope this helps. CN Capt. Neal thinks I'm wrong. I rest my case! :-) P. |
#26
![]() |
|||
|
|||
![]()
"James Hahn" wrote in message
news ![]() "Meindert Sprang" wrote in message ... snip There are two possible scenarios: one battery wears more quickly than the other, eventually reaching a state where the cell voltages reach higher values due to increasing internal resistance. Thus the charges shuts off too early, leaving the better battery not topped up. The charger does not monitor cell voltages. It monitors the voltage across all the cells in series. That is exactly what I meant and exactly the reason why it can go wrong. So I would like to invite you to shoot holes in my following argument: The charge of a battery is the product of current x time. Both batteries are in series and one load is connected to the set, operating at 24V. Another load is connected across only one battery, operating at 12V. So it is evident that one battery is discharged more than the other. I start to charge the set in series, so the current through both batteries is exactly the same. Since one battery is discharged more than the other and the current throug both is the same, one battery must be charged longer that the other. Exactly how am I going to achive that with the same current through both batteries? One battery will reach the full state before the other but is still being charged with full current because the other battery hasn't reached the voltage that corresponds with full charge. Now, if you can come up with an valid argument why this shouldn't damage one battery, I bow and take my hat off. Meindert |
#27
![]() |
|||
|
|||
![]()
Hello Meindert,
I agree with your analysis and go a step beyond: even if there is no differential load across one of the batteries, uneven charging is possible (or likely) because of differences in the batteries themselves. Regards, Chuck Meindert Sprang wrote: "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip There are two possible scenarios: one battery wears more quickly than the other, eventually reaching a state where the cell voltages reach higher values due to increasing internal resistance. Thus the charges shuts off too early, leaving the better battery not topped up. The charger does not monitor cell voltages. It monitors the voltage across all the cells in series. That is exactly what I meant and exactly the reason why it can go wrong. So I would like to invite you to shoot holes in my following argument: The charge of a battery is the product of current x time. Both batteries are in series and one load is connected to the set, operating at 24V. Another load is connected across only one battery, operating at 12V. So it is evident that one battery is discharged more than the other. I start to charge the set in series, so the current through both batteries is exactly the same. Since one battery is discharged more than the other and the current throug both is the same, one battery must be charged longer that the other. Exactly how am I going to achive that with the same current through both batteries? One battery will reach the full state before the other but is still being charged with full current because the other battery hasn't reached the voltage that corresponds with full charge. Now, if you can come up with an valid argument why this shouldn't damage one battery, I bow and take my hat off. Meindert |
#28
![]() |
|||
|
|||
![]() "Meindert Sprang" wrote in message ... "James Hahn" wrote in message news ![]() "Meindert Sprang" wrote in message ... snip There are two possible scenarios: one battery wears more quickly than the other, eventually reaching a state where the cell voltages reach higher values due to increasing internal resistance. Thus the charges shuts off too early, leaving the better battery not topped up. The charger does not monitor cell voltages. It monitors the voltage across all the cells in series. That is exactly what I meant and exactly the reason why it can go wrong. So I would like to invite you to shoot holes in my following argument: The charge of a battery is the product of current x time. Both batteries are in series and one load is connected to the set, operating at 24V. Another load is connected across only one battery, operating at 12V. So it is evident that one battery is discharged more than the other. I start to charge the set in series, so the current through both batteries is exactly the same. Since one battery is discharged more than the other and the current throug both is the same, one battery must be charged longer that the other. Exactly how am I going to achive that with the same current through both batteries? One battery will reach the full state before the other but is still being charged with full current because the other battery hasn't reached the voltage that corresponds with full charge. Now, if you can come up with an valid argument why this shouldn't damage one battery, I bow and take my hat off. Meindert Duh! the two batteries are in series. The one with the 12v tap cannot become more discharged than the one without because the battery without the tap will charge the one with. Or the one with will discharge the one without until they are both the same. This is the same thing that happens with individual cells in a 12v battery. With two 12v batteries in a series one simply has more cells in a series. CN |
#29
![]() |
|||
|
|||
![]()
Why all this ranting over a proven fact that drawing 12V off of one battery
of a 24V bank is not a good idea? A 40 amp 24/12 DC/DC converter capable of running all the electronics on the boat can be bought for the price of a couple of golf cart batteries. This is nonsense! -- Glenn Ashmore I'm building a 45' cutter in strip/composite. Watch my progress (or lack there of) at: http://www.rutuonline.com Shameless Commercial Division: http://www.spade-anchor-us.com "Nigel" wrote in message ... I have a 24v electrical set up on my boat, but need a 12v supply for my VHF (amongst other things). Is there any reason why I can't just run a 12v supply from just one of a pair of batteries, or do I need to use a 24v/12v converter. I release this will draw charge from just one battery , but won't the other just top it up and there by drain them both equally Thanks |
#30
![]() |
|||
|
|||
![]()
In article ,
"Meindert Sprang" wrote: That is exactly what I meant and exactly the reason why it can go wrong. So I would like to invite you to shoot holes in my following argument: The charge of a battery is the product of current x time. Both batteries are in series and one load is connected to the set, operating at 24V. Another load is connected across only one battery, operating at 12V. So it is evident that one battery is discharged more than the other. I start to charge the set in series, so the current through both batteries is exactly the same. Since one battery is discharged more than the other and the current throug both is the same, one battery must be charged longer that the other. Exactly how am I going to achive that with the same current through both batteries? One battery will reach the full state before the other but is still being charged with full current because the other battery hasn't reached the voltage that corresponds with full charge. Now, if you can come up with an valid argument why this shouldn't damage one battery, I bow and take my hat off. Meindert One thing you left out, Meindert, is the fact that the 12Vdc load is still there, and consuming part of the charging current across that battery, which only makes the problem worse..... bruce in alaska -- add a 2 before @ |