Home |
Search |
Today's Posts |
#17
![]() |
|||
|
|||
![]() "Glenn Ashmore" wrote in message ... Ed Price wrote: So I looked at the Xantrex site, trying to get some idea of a Zap-stop's performance. I couldn't find a circuit diagram for how the Zap-stop is hooked up to the alternator. Xantrex says something about connection across the rectifiers, but that isn't clear enough for me. Also, Xantrex doesn't say anything about how fast the Zap-stop begins to conduct when presented with a voltage excursion. Does Xantrex have some hard data on their product, or do they just expect you to trust them? The Zap Stop connects between the alternator output and ground. It is just a high voltage diode with a reverse breakdown voltage a bit higher than the operating voltage of the alternator. When the voltage exceeds this level the diode starts to conduct instantly shorting it to ground. The alternator diodes are designed for high amperage at relatively low voltages. The Zap Stop diode is designed for high voltages but will only handle high amperage for the few milliseconds it takes for the regulator to regain control. I don't think it could stand up to something like a loose sense wire on a high amperage alternator where the voltage and amp output stays high for any length of time. -- Glenn Ashmore If the Zap-stop is connected to the alternator output, then it is positioned best to protect the alternator against transients originating in the rest of the vehicle's electrical system. (The worst source might be a high-current motor, like the AC blower fan.) OTOH, earlier posts have said that the sudden removal of load causes a high voltage transient in the alternator's windings. This means that the Zap-stop protects the alternator diodes from a high voltage by requiring the diodes to pass a massive current transient into the Zap-stop and to ground. That's strange protection! If you wanted to protect against an alternator winding over-voltage, wouldn't you have to put the protection at the winding side of the alternator diodes? The last time I looked inside an alternator, it had three field windings connected to a 6-diode full-wave bridge rectifier. Protecting the bridge against voltage transients would require one Zap-stop type device across each winding. An over-voltage event would then conduct through the Zap-stop devices, and not through the alternator diodes. Could all of this discussion have been based on a misconception of what happens when a heavy load current (into an inductive load like a motor winding). The potentially damaging transient is caused by the counter emf from the load, and not from any "slow regulator" effect within the alternator. If the Zap-stop is mounted to the alternator output lug, then that's apparently what the Zap-stop is configured to protect against. Ed |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Divers Needed for bottom cleaning & zincs in SF Bay | Boat Building | |||
Advice Needed: Yam 701 Starting To Smoke Too Much | Cruising | |||
Scientists needed for TV series | General | |||
Advice needed: seat vinyl rip repair | Cruising |