On Oct 2, 1:37 pm, "Lew Hodgett" wrote:
wrote: A wet cell battery can accept an average of 15% of it's AH capacity as a recharge rate over the charging cycle. Thus, a 400AH bank will accept 60A recharge average over the recharge cycle. Lew Hi Lew: Thanks for the info. I forgot to mention,, yes I have four wet cell 6v T-105s. Another question...... is there a minimum Ah charge rate for a 3 step charger? That is if I increase my house bank up to 600-800 Ah would it freak out a 30 amp charger if the bank was down to 30% of capacity?? Some where I heard the charger may sense the " emptyness" and consider it a short...... Any truth to this or just more dock talk? Chris |