I've had very good luck with this very simple set up shown on this and the
following page.

http://home.maine.rr.com/rlma/Strider0601.htm

No "Y" valve, no macerator pump. You have to pump by hand but, hey, we
could all use a little exercise at our age.

There is no direct overboard discharge I find pumping out the tank
occasionally less trouble than remembering to constantly switch back and
forth as we move in and out of no-discharge zones. In our home waters, we
usually have to make a special diversion to get to an area where we can
pump. Most pumping is dond at the dock.

The deck fitting seals well enough that the hand pump sucks through the "T".
When back flushing the tank with fresh water, I open the discharge pump the
hand pump a few strokes as the FW runs to clear the discharge lines.

If you have a small crew and primarily pump at the dock, this is a very
simple and workable set up.

Someone will point out the lack of a vented loop on the discharge. Save
your fingers. The through hull is only open when pumping and never needs to
be operated by a crew or guest. Even if it was left open, the water would
have to flow against two one way valves in the pump, fill the tank, and then
flow against the joker valve. It might sink the boat after a few weeks at
the dock but it's on the leaving boat checklist. Not having to pump
through the longer pipe or having a siphon break to leak odors from a dirtly
line makes the very slight risk worthwhile. If I ever need a survey for
insurance, I'm sure I'll have a fight with the surveyor though.

"krj" wrote in message
...
Peggy,
I am re-plumbing my holding tank to include a macerator pump, Y-valve, and
through hull. The easiest way to mount the macerator pump is to screw it
into the outlet of the tank then plumb to the y-valve. Question is, will
the pump out be able to suck through the pump or can I turn the pump on
while pumping out the tank. Also is there any problem with pushing stuff
through the Y-valve rather than pulling through the valve.
Thanks
krj



  #2   Report Post  
posted to rec.boats.cruising
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 1,301
Default Question for Peggy

I've often wondered it this setup requires a "lock" on the pumpout to
comply with 33CFR159. Most descriptions of the reg refer to
"preventing accidental discharge" or securing a "direct discharge"
line. It would appear that the chance of an "accident" on your system
is essentially nil. Mine is similar, except that it includes a
y-valve to allow for either a manual pump discharge, or a deck
pumpout. Since the y-valve looks like one that might permit direct
discharge, I often keep a cable tie on it. I could also lock the
hatch or hide the pump handle, but I'd probably lose the key or handle!

Unfortunately, the actually CFR doesn't actually mention "accidental"
or "direct discharge." It more generally requires securing any means
of discharge. If the holding tank is considered part of the MSD Type
III system, then it would seem its pumping system would be included.

33CFR159.7


Roger Long wrote:
I've had very good luck with this very simple set up shown on this and the
following page.

http://home.maine.rr.com/rlma/Strider0601.htm

No "Y" valve, no macerator pump. You have to pump by hand but, hey, we
could all use a little exercise at our age.

....
  #3   Report Post  
posted to rec.boats.cruising
external usenet poster
 
First recorded activity by BoatBanter: Nov 2006
Posts: 405
Default Question for Peggy

I remove the thru hull handle and keep it cable tied to the hose. No way
anyone will confuse it with inlet valve and I'm covered if the Coast Guard
boards.

"Jeff" wrote in message
. ..
I've often wondered it this setup requires a "lock" on the pumpout to


--
Roger Long


  #4   Report Post  
posted to rec.boats.cruising
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 105
Default Question for Peggy

Jeff wrote:
I've often wondered it this setup requires a "lock" on the pumpout to
comply with 33CFR159.


It doesn't...Only valves and/or seacocks connected to overboard
discharge thru-hulls must be secured:

33CFR159 sayeth:


(c) When operating a vessel on a body of water where the discharge of
untreated sewage is prohibited by the Environmental Protection Agency
under 40 CFR 140.3, the operator must secure each Type III device in a
manner which prevents discharge of sewage. Acceptable methods of
securing the device include—

(1) Closing each valve leading to an overboard discharge and removing
the handle;

(2) Padlocking each valve leading to an overboard discharge in the
closed position; or

(3) Using a non-releasable wire-tie to hold each valve leading to an
overboard discharge in the closed position.

No mention of the pumpout line at all.

However, inland may be another story. The Great Lakes and all non-navigable
inland lakes are “no discharge” waters. They’re also a loooong way
from the ocean. Since there's no possible way to legally use a
y-valve or macerator to dump a tank, many states have made it illegal
for vessels operating on these waters even to have one or both
installed. When in doubt, check with your local authorities.


Most descriptions of the reg refer to "preventing
accidental discharge" or securing a "direct discharge" line.


There are no adjectives in the wording of the CFR (which I copy/pasted
directly from it above)...just "discharge."

If the holding tank is considered part of the MSD Type
III system, then it would seem its pumping system would be included.


Any means of pumping sewage overboard IS included. The CFR defines
"discharge" as: "includes, but is not limited to, any spilling, leaking,
pouring, pumping, emitting, emptying, or dumping." The deck pumpout
fitting would automatically be "secure" as long as no hose going over
the side is connnected to it.


--
Peggie
----------
Peggie Hall
Specializing in marine sanitation since 1987
Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and
Other Sources of Aggravation and Odor"
http://shop.sailboatowners.com/books...ku=90&cat=1304
  #5   Report Post  
posted to rec.boats.cruising
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 1,301
Default Question for Peggy

Sorry Peggie, what I meant was the onboard pump that was shown in the
picture, not the deck pumpout fitting. I had assumed that my setup,
and Roger's, was legal because because it didn't come directly from
the head, but a closer reading of the CFR shows, as you say, that any
line that could be used to discharge overboard, is included and must
be secured.

Peggie Hall wrote:
Jeff wrote:
I've often wondered it this setup requires a "lock" on the pumpout to
comply with 33CFR159.


It doesn't...Only valves and/or seacocks connected to overboard
discharge thru-hulls must be secured:

33CFR159 sayeth:


(c) When operating a vessel on a body of water where the discharge of
untreated sewage is prohibited by the Environmental Protection Agency
under 40 CFR 140.3, the operator must secure each Type III device in a
manner which prevents discharge of sewage. Acceptable methods of
securing the device include—

(1) Closing each valve leading to an overboard discharge and removing
the handle;

(2) Padlocking each valve leading to an overboard discharge in the
closed position; or

(3) Using a non-releasable wire-tie to hold each valve leading to an
overboard discharge in the closed position.

No mention of the pumpout line at all.

However, inland may be another story. The Great Lakes and all
non-navigable
inland lakes are “no discharge” waters. They’re also a loooong way
from the ocean. Since there's no possible way to legally use a
y-valve or macerator to dump a tank, many states have made it illegal
for vessels operating on these waters even to have one or both
installed. When in doubt, check with your local authorities.


Most descriptions of the reg refer to "preventing
accidental discharge" or securing a "direct discharge" line.


There are no adjectives in the wording of the CFR (which I copy/pasted
directly from it above)...just "discharge."

If the holding tank is considered part of the MSD Type
III system, then it would seem its pumping system would be included.


Any means of pumping sewage overboard IS included. The CFR defines
"discharge" as: "includes, but is not limited to, any spilling, leaking,
pouring, pumping, emitting, emptying, or dumping." The deck pumpout
fitting would automatically be "secure" as long as no hose going over
the side is connnected to it.




  #6   Report Post  
posted to rec.boats.cruising
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 105
Default Question for Peggy

Jeff wrote:
Sorry Peggie, what I meant was the onboard pump that was shown in the
picture, not the deck pumpout fitting. I had assumed that my setup, and
Roger's, was legal because because it didn't come directly from the
head, but a closer reading of the CFR shows, as you say, that any line
that could be used to discharge overboard, is included and must be secured.


It's legal. Since there is no y-valve, wire tying the seacock handle and
removing it, or removing the handle from the pump, or both, secures the
system.

Peggie



Peggie Hall wrote:
Jeff wrote:
I've often wondered it this setup requires a "lock" on the pumpout to
comply with 33CFR159.


It doesn't...Only valves and/or seacocks connected to overboard
discharge thru-hulls must be secured:

33CFR159 sayeth:


(c) When operating a vessel on a body of water where the discharge of
untreated sewage is prohibited by the Environmental Protection Agency
under 40 CFR 140.3, the operator must secure each Type III device in a
manner which prevents discharge of sewage. Acceptable methods of
securing the device include—

(1) Closing each valve leading to an overboard discharge and removing
the handle;

(2) Padlocking each valve leading to an overboard discharge in the
closed position; or

(3) Using a non-releasable wire-tie to hold each valve leading to an
overboard discharge in the closed position.

No mention of the pumpout line at all.

However, inland may be another story. The Great Lakes and all
non-navigable
inland lakes are “no discharge” waters. They’re also a loooong way
from the ocean. Since there's no possible way to legally use a
y-valve or macerator to dump a tank, many states have made it illegal
for vessels operating on these waters even to have one or both
installed. When in doubt, check with your local authorities.


Most descriptions of the reg refer to "preventing
accidental discharge" or securing a "direct discharge" line.


There are no adjectives in the wording of the CFR (which I copy/pasted
directly from it above)...just "discharge."

If the holding tank is considered part of the MSD Type
III system, then it would seem its pumping system would be included.


Any means of pumping sewage overboard IS included. The CFR defines
"discharge" as: "includes, but is not limited to, any spilling,
leaking, pouring, pumping, emitting, emptying, or dumping." The deck
pumpout fitting would automatically be "secure" as long as no hose
going over the side is connnected to it.




--
Peggie
----------
Peggie Hall
Specializing in marine sanitation since 1987
Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and
Other Sources of Aggravation and Odor"
http://shop.sailboatowners.com/books...ku=90&cat=1304
Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Another strip-plank question - a bit long Pete Boat Building 3 January 12th 04 08:03 PM
Propeller efficiency question (electric) MBS Boat Building 4 December 23rd 03 04:39 AM
Other choice and counterpoise question Earl Haase Electronics 3 October 31st 03 06:43 PM
Exhaust question on inboard 1958 Chris Craft Gary Warner Boat Building 5 September 25th 03 12:32 AM
Sunday's VHF antics.....and a question.. Electronics 8 September 13th 03 09:04 AM


All times are GMT +1. The time now is 10:47 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017