Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Steve
 
Posts: n/a
Default Plumbing the Watermaker output?

Your assuming that your salinity divertor is 'fool proof'??

You may be correct because, while using the product water as it is being
delivered, you would stand a better chance of noticing your coffee is a bit
salty.

My set up will deliver the product water to the tank fill manifold..

I may rethink this since I could fill a tank with bad water and never know
it.

I was onboard a friends boat and he had the product water line coming to his
galley sinks where it ran down the drain until he took a final "taste"
sample.. If it was good, he turned a 3 way valve that sent it to the tanks.

My HRO system has a remote control/indicator panel with both audible and
visual alarms to indicate any fault in the system or product water.. I
haven't installed it yet, seems to complicate the system too much.

I kinda like my friends simple method. KISS..

Steve
s/v Good Intentions


  #2   Report Post  
Glenn Ashmore
 
Posts: n/a
Default Plumbing the Watermaker output?

You know me better than that! To me KISS is something that gives you
Mono or Hepatitis. :-)

This system is a result of 30 years in the software business learning
never to completely trust a computer. :-) It is as automated as I can
make it with push button operation and auto backflush but with mandatory
human intervention at critical points and manual overrides everywhere.

I added a Hanna electronic TDS sensor wired to a 3-way solenoid. When
the TDS drops to acceptable levels the product diverts to a second
solenoid and that outputs to the manual sampling tap that I think I
will mound near the helm. If it taste OK I push a button to send it to
the tanks.

Steve wrote:
Your assuming that your salinity divertor is 'fool proof'??

You may be correct because, while using the product water as it is being
delivered, you would stand a better chance of noticing your coffee is a bit
salty.

My set up will deliver the product water to the tank fill manifold..

I may rethink this since I could fill a tank with bad water and never know
it.

I was onboard a friends boat and he had the product water line coming to his
galley sinks where it ran down the drain until he took a final "taste"
sample.. If it was good, he turned a 3 way valve that sent it to the tanks.

My HRO system has a remote control/indicator panel with both audible and
visual alarms to indicate any fault in the system or product water.. I
haven't installed it yet, seems to complicate the system too much.

I kinda like my friends simple method. KISS..

Steve
s/v Good Intentions




--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com

  #3   Report Post  
Fred Williams
 
Posts: n/a
Default Plumbing the Watermaker output?

Don't really know how your waatermaker works but what happens if the output
goes "sour" after you have sampled and redirected it? I would guess the
"automated" monitor you mentioned is most likely "real time" and should
catch a failure at any time during a watermaker run.

Fred

"Glenn Ashmore" wrote in message
...
You know me better than that! To me KISS is something that gives you
Mono or Hepatitis. :-)

This system is a result of 30 years in the software business learning
never to completely trust a computer. :-) It is as automated as I can
make it with push button operation and auto backflush but with mandatory
human intervention at critical points and manual overrides everywhere.

I added a Hanna electronic TDS sensor wired to a 3-way solenoid. When
the TDS drops to acceptable levels the product diverts to a second
solenoid and that outputs to the manual sampling tap that I think I
will mound near the helm. If it taste OK I push a button to send it to
the tanks.

Steve wrote:
Your assuming that your salinity divertor is 'fool proof'??

You may be correct because, while using the product water as it is being
delivered, you would stand a better chance of noticing your coffee is a

bit
salty.

My set up will deliver the product water to the tank fill manifold..

I may rethink this since I could fill a tank with bad water and never

know
it.

I was onboard a friends boat and he had the product water line coming to

his
galley sinks where it ran down the drain until he took a final "taste"
sample.. If it was good, he turned a 3 way valve that sent it to the

tanks.

My HRO system has a remote control/indicator panel with both audible and
visual alarms to indicate any fault in the system or product water.. I
haven't installed it yet, seems to complicate the system too much.

I kinda like my friends simple method. KISS..

Steve
s/v Good Intentions




--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com



  #4   Report Post  
Glenn Ashmore
 
Posts: n/a
Default Plumbing the Watermaker output?

As a watermaker membrane ages and fouls it produces less fresh water but
the salts don't increase. The TDS sensor would divert the product water
if it did get over 200 ppm or so but that is not likely to happen. The
main reason for testing and discarding the first water out is that it
will be salty.

Remember that the process is "REVERSE" osmosis. The high pressure
reverses the natural tendency for salty water to migrate through a
membrane to less salty water. With no pressure the natural process
resumes and salt passes through and accumulates on the fresh water side.

Fred Williams wrote:
Don't really know how your waatermaker works but what happens if the output
goes "sour" after you have sampled and redirected it? I would guess the
"automated" monitor you mentioned is most likely "real time" and should
catch a failure at any time during a watermaker run.


--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com

  #5   Report Post  
Skip Gundlach
 
Posts: n/a
Default Plumbing the Watermaker output?

Leaving the below in for context, are you going to put your configuration on
your website? I'm sure others might like to attempt your achievements at
bargain hunting and efficacy...

L8R

Skip
"Glenn Ashmore" wrote in message
...
As a watermaker membrane ages and fouls it produces less fresh water but
the salts don't increase. The TDS sensor would divert the product water
if it did get over 200 ppm or so but that is not likely to happen. The
main reason for testing and discarding the first water out is that it
will be salty.

Remember that the process is "REVERSE" osmosis. The high pressure
reverses the natural tendency for salty water to migrate through a
membrane to less salty water. With no pressure the natural process
resumes and salt passes through and accumulates on the fresh water side.

Fred Williams wrote:
Don't really know how your waatermaker works but what happens if the

output
goes "sour" after you have sampled and redirected it? I would guess the
"automated" monitor you mentioned is most likely "real time" and should
catch a failure at any time during a watermaker run.


--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com





  #6   Report Post  
Glenn Ashmore
 
Posts: n/a
Default Plumbing the Watermaker output?

Yes. The pressure vessels just arrived and I will have the installation
complete enough to finish the picture series for the web oage. I have
converted the schematics and printed circuits to GIFs and have been
working on the narative.

Hopefully I can get some stuff up on the server next week and reduce the
volume of emails from impatient site visitors. :-)

Skip Gundlach wrote:
Leaving the below in for context, are you going to put your configuration on
your website? I'm sure others might like to attempt your achievements at
bargain hunting and efficacy...

L8R

Skip
"Glenn Ashmore" wrote in message
...

As a watermaker membrane ages and fouls it produces less fresh water but
the salts don't increase. The TDS sensor would divert the product water
if it did get over 200 ppm or so but that is not likely to happen. The
main reason for testing and discarding the first water out is that it
will be salty.

Remember that the process is "REVERSE" osmosis. The high pressure
reverses the natural tendency for salty water to migrate through a
membrane to less salty water. With no pressure the natural process
resumes and salt passes through and accumulates on the fresh water side.

Fred Williams wrote:

Don't really know how your waatermaker works but what happens if the


output

goes "sour" after you have sampled and redirected it? I would guess the
"automated" monitor you mentioned is most likely "real time" and should
catch a failure at any time during a watermaker run.


--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com






--
Glenn Ashmore

I'm building a 45' cutter in strip/composite. Watch my progress (or lack
there of) at: http://www.rutuonline.com
Shameless Commercial Division: http://www.spade-anchor-us.com

Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Tachometer output on 50 Hp Mercury four stroke Rod McInnis General 4 June 25th 04 01:01 PM
Fresh Water System Design Ideas. Aluminumhullsailor Boat Building 11 September 12th 03 07:12 AM


All times are GMT +1. The time now is 05:36 PM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017