On Sep 15, 6:49*pm, John H. wrote:
No, Tim, it's one of these buggers:http://tinyurl.com/69jflb The one on the trailer. Once the outside temp cooled down, in the evening, the AC ran fine. But during the hottest part of the day, the thing would trip the circuit breaker no matter how we adjusted the settings. I found a web site, so I'll do a little research. -- John H. My opinions. #1 weak breaker, but doubtful. #2 defective fan that "drags" a bit too much, but doubtful #3, compressor is having to work extended time due to higher temps. Very possible. #4 not recirculating inside air because the fresh air vent is open ( or at least not closing) drawing moisture causing the evaporator coil to frost over especially in high humidity. #5 it could be a clogged filter, AND/OR clogged condenser coil. That is if it is a used unit. #6 too much freon. If it's been recharged in the past, sometimes they cram too much freon into the thing, because they want it to be colder than cold. But what happens is it over loads the compressor Like previously mentioned, if it's under warranty then nit-pick them to death until they fix it. |
#2
![]()
posted to rec.boats
|
|||
|
|||
![]()
On Mon, 15 Sep 2008 17:40:48 -0700 (PDT), Tim wrote:
On Sep 15, 6:49*pm, John H. wrote: No, Tim, it's one of these buggers:http://tinyurl.com/69jflb The one on the trailer. Once the outside temp cooled down, in the evening, the AC ran fine. But during the hottest part of the day, the thing would trip the circuit breaker no matter how we adjusted the settings. I found a web site, so I'll do a little research. -- John H. My opinions. #1 weak breaker, but doubtful. #2 defective fan that "drags" a bit too much, but doubtful #3, compressor is having to work extended time due to higher temps. Very possible. #4 not recirculating inside air because the fresh air vent is open ( or at least not closing) drawing moisture causing the evaporator coil to frost over especially in high humidity. #5 it could be a clogged filter, AND/OR clogged condenser coil. That is if it is a used unit. #6 too much freon. If it's been recharged in the past, sometimes they cram too much freon into the thing, because they want it to be colder than cold. But what happens is it over loads the compressor Like previously mentioned, if it's under warranty then nit-pick them to death until they fix it. Thanks Tim. Lots of possibilities, but some of them I can check. I'll do so tomorrow. Thanks again. -- John H. |
Reply |
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
Oh, shit. It happened to me. | Cruising | |||
HOLY SHIT! | ASA | |||
I smell Cat Shit | ASA | |||
Bob = Cat SHIT | ASA | |||
Need to pump shit? | General |