My boat also goes through zincs in 100 days +/-. I have a GI installed. How
can I tell if my boat is the problem or if it's neighbors or the marina
(without disconnecting from shore power for 90 days :-) )?

Mike


"Andina Marie" wrote in message
oups.com...
By far the majority of accelerated zinc loss cause is the shore power
connection.
The first step is to install a galvanic isolator.
Defender has them on sale for about $95 at
http://www.defender.com/product.jsp?path=-1|328|303336&id=605562


Regards,

Ann-Marie Foster,




  #2   Report Post  
posted to rec.boats.electronics
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 50
Default Zinc is dissappearing FAST!

Mike wrote:
My boat also goes through zincs in 100 days +/-. I have a GI installed. How
can I tell if my boat is the problem or if it's neighbors or the marina
(without disconnecting from shore power for 90 days :-) )?

Mike


Hello Mike,

First thing is buy a copy of "The 12
Volt Doctor's Practical Handbook" at
your local marine store.

With a simple DMM you can do some
testing to answer your question. You can
even test neighboring boats if you can
clamp a test lead onto a shroud or
grounded piece of metal. Some folks will
have strong feelings about this
"trespassing" but you need not board the
vessel and will not mar it or subject it
to damage in any way by the testing. If
you know the owner, you may even find
him willing to participate.

Anyway, you need to disconnect the shore
power only for the duration of the test,
which should be less than 5 minutes.

Read the (very short) book and post any
questions you have.

Having said all that, I must say that
100 days is too short a period for zinc
life. There are many possibilities,
starting with whether your zincs are too
small. Did you notice a difference in
zinc life when you installed the GI? Can
you triple the zinc size easily? Have
you considered a supplemental zinc
hanging over the side? Good to have one
on board anyway.

Good luck.

Chuck

----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----
  #4   Report Post  
posted to rec.boats.electronics
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 2
Default Zinc is dissappearing FAST!

I understand how NO ground connection is better than a typical setup with an
isolator, but if the isolator is functioning, isn't the effect very close to
the same?

Let me ask it another way. If I have about 0.2 VDC across the galvanic
isolator, would I see about the same between the shore ground and
neutral/ground on the boat side of an isolation transformer?

"Larry" wrote in message
...
"Mike" wrote in news:b8idnTRka-tz-
:

(without disconnecting from shore power for 90 days :-) )?



Install an isolation transformer with an ISOLATED GROUND. That allows the
AC to flow across the transformer windings but not the galvanic current,
which is DC.....unless some idiot hooks you boat ground to the dock ground
rendering the isolation useless.



  #5   Report Post  
posted to rec.boats.electronics
external usenet poster
 
First recorded activity by BoatBanter: Jul 2006
Posts: 50
Default Zinc is dissappearing FAST!

Mike wrote:
I understand how NO ground connection is better than a typical setup with an
isolator, but if the isolator is functioning, isn't the effect very close to
the same?

Let me ask it another way. If I have about 0.2 VDC across the galvanic
isolator, would I see about the same between the shore ground and
neutral/ground on the boat side of an isolation transformer?


Larry may have answered your question
indirectly.

The short answer is yes. If you follow
the recommended practice of using one of
the transformer secondary wires as a
combination neutral/ground, then you
would measure the same 0.2 volts from
there to the shore power ground.

Chuck

----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Fast Boats and the REAL WORLD Capt. Rob ASA 28 July 18th 06 02:22 AM
So where is...................... *JimH* General 186 November 28th 05 02:29 PM
Where is the @$%#!! zinc in a Westerbeke 30????? Jon Klapper Cruising 7 June 10th 04 03:01 AM
Zinc is gone in 3 months Rob General 9 April 13th 04 01:17 AM
Save your wasted zinc stubs! Gould 0738 General 11 October 13th 03 03:53 PM


All times are GMT +1. The time now is 05:37 AM.

Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004-2025 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017