I think I said that, two paragraphs further along. I guess I assume
that on a post with a lot of techincal content, that the reader will wade through the whole thing before going out and spending money. Jim Jim wrote in message ... Jim Woodward wrote: Lee: snip However, the good news is that any transformer is an isolation transformer for our purposes -- snip This is not correct. An autotransformer has a single winding and does not provide isolation. Jim |
#12
![]() |
|||
|
|||
![]()
Jim,
Thanks for all the information, leads, and offers. At this point, I do not have enough knowledge to make any kind of informed choice regarding an isolation transformer. Can you direct me to a source where I can read and learn more of what I need to know? Lee Huddleston |
#13
![]() |
|||
|
|||
![]() AFAIK, there is only one that meets the ABYC specs, & that is made by Charles Industries (www.charlesindustries.com). Something about isolaitng the ground as well as the conductors. Michael Porter (Lee Huddleston) wrote: Jim, Would you have a recommendation for an isolation transformer? The only one that I have found so far ate up a lot of the power before it could get into the boat. That seemed strange to me, but maybe I was reading the specs incorrectly. Also the price seemed to be very high. Of course, protecting my beloved boat from galvanic corrosion is probably worth a lot if that is what is necessary. By the way, you mentioned DC and AC ground fault alarms. Who makes them and are they available to private individuals? Thanks in advance for your help. Lee Michael Porter Naval Architect / Boatbuilder mporter at mp-marine dot com www.mp-marine.com |
#14
![]() |
|||
|
|||
![]()
First the usual CYA stuff -- electricity can be dangerous in a whole
variety of ways. If you don't understand it, hire an expert. There's a lot of good information available on the web, including here, but good electrical practice finally comes down to details that you need to do because you've learned, somewhere, to do them right. And BTW, a boat is not a house, so a license to do wiring ashore says nothing about a person's skills in wiring boats. With that said, an isolation transformer is a pretty simple device -- two wires in and two wires out -- although there are often a lot more leads than two, as they can usually be connected for different or multiple voltages. Figuring out the leads is like figuring out how to wire a 120/240VAC motor -- it's just cookbook and often there's a diagram. If not, we have ways.... I usually refer people to Nigel Calder's Boatowner's Mechanical and Electrical Manual for all mechanical and electrical stuff -- in this case there's a diagram and a couple of paragraphs. This is not a bad little piece on the subject: http://www.smpstech.com/qa/qa0002.htm This has more than any ordinary mortal needs to know, but a number of details can be picked out if you're strong enough to ingnore the heavy math. http://www.du.edu/~jcalvert/tech/transfor.htm Aside from actually connecting the thing, the only other issue is sizing. Generally, if you plug into a standard 30A 120V shore outlet, you'll want a 3.6kw transformer (30x120 ~=~ 3.6kw). Larger won't hurt (other than being heavier) within broad limits. Smaller is OK, too, provided you put a circuit breaker on the shore side of the transformer that is the same rating as the transformer. Of course, smaller means you can't run as much stuff.... If you have a larger boat and regularly use 240VAC, then you can run 50A 240 from standard marina outlets, but this takes a 12kw transformer, which is starting to get heavy and pricey. Don't forget, it's got to mounted somewhere that can stand a big weight, is dry, and won't get too hot with a couple of hundred watts being thrown off. It may hum a little, so you won't want it as a pillow. Jim Woodward www.mvFintry.com (Lee Huddleston) wrote in message . .. Jim, Thanks for all the information, leads, and offers. At this point, I do not have enough knowledge to make any kind of informed choice regarding an isolation transformer. Can you direct me to a source where I can read and learn more of what I need to know? Lee Huddleston |
#15
![]() |
|||
|
|||
![]() I usually refer people to Nigel Calder's Boatowner's Mechanical and Electrical Manual for all mechanical and electrical stuff -- in this case there's a diagram and a couple of paragraphs. I have the Nigel Calder book and have almost committed it to memory. That is what caused me to want an isolation transformer in the first place. This is not a bad little piece on the subject: http://www.smpstech.com/qa/qa0002.htm Yes, it does give some good information. This has more than any ordinary mortal needs to know, but a number of details can be picked out if you're strong enough to ingnore the heavy math. http://www.du.edu/~jcalvert/tech/transfor.htm Wow! "Ask and ye shall receive." Thanks. I will reread this material until I think that I understand most of it. If I can do that, I doubt that there will be much about transformers that I will not know. Aside from actually connecting the thing, the only other issue is sizing. Generally, if you plug into a standard 30A 120V shore outlet, you'll want a 3.6kw transformer (30x120 ~=~ 3.6kw). The smallest isolation transformer made by Charles Industries, recommended in the next post, just happens to be their 3.6kw transformer. Looks like a good lead. Thank you very much for all your help. Lee Huddleston s/v Truelove |
#16
![]() |
|||
|
|||
![]() AFAIK, there is only one that meets the ABYC specs, & that is made by Charles Industries (www.charlesindustries.com). Something about isolaitng the ground as well as the conductors. Michael Porter Michael, Thanks for the lead. The smallest Charles Industries transformer is just the size that Jim Woodward recommends. Looks like a good possibility. BTW, I could not figure out how to find the price on the transformer. Have I just overlooked it on the web site or will I just need to give them a call? Lee Huddleston s/v Truelove |