Reply
 
LinkBack Thread Tools Search this Thread Display Modes
  #1   Report Post  
Geoffrey W. Schultz
 
Posts: n/a
Default 3 stage regulator questions

Sounds like 1 state (bulk) charging to me. It should hold at acceptance
level (bulk charging voltage) while the amperage is reduced. Then it
should drop to the float level, which is typically around 13.2 V.
Something isn't working right unless you float level is set to the same
level as bulk, which is wrong as far as I know.

-- Geoff

jeannette wrote in
:

Hi group,

I bought an alternator with a built-in 3 stages regulator. The voltage
coming out of it seems to be constant at 14.40v. The batteries are
fully charged now and the charge current is very small (1amp) but the
voltage remain at 14.40v. Is that normal?. I am told by the
manufacturer that it's the way it should be. I would have thought that
the voltage should come down to a lower level once the batteries are
full.

What do you think?


Jeannette Bristol 32, San Francisco
http://www.eblw.com/contepartiro/contepartiro.html


Reply
Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

Posting Rules

Smilies are On
[IMG] code is Off
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Similar Threads
Thread Thread Starter Forum Replies Last Post
Desalination by 2 stage nano filtration not RO - what's the difference? Panama Cruising 2 November 15th 03 01:23 AM
3 stage charging question Rick & Linda Bernard Cruising 2 August 14th 03 10:22 PM


All times are GMT +1. The time now is 06:45 AM.

Powered by vBulletin® Copyright ©2000 - 2024, Jelsoft Enterprises Ltd.
Copyright ©2004-2024 BoatBanter.com.
The comments are property of their posters.
 

About Us

"It's about Boats"

 

Copyright © 2017