santacruz April 23rd 04 09:42 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Somewhere I thought I saw a 3rd mfg of threaded terminals like stalok,
norseman - anybody remember the name?



jeannette April 24th 04 03:23 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Could it be them?: http://www.suncorstainless.com/sscart/index2.html

Jeannette

On Fri, 23 Apr 2004 13:42:53 -0700, santacruz
wrote:

Somewhere I thought I saw a 3rd mfg of threaded terminals like stalok,
norseman - anybody remember the name?


Jeannette
aa6jh
Bristol 32, San Francisco
http://www.eblw.com/contepartiro/contepartiro.html

jeannette April 24th 04 03:23 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Could it be them?: http://www.suncorstainless.com/sscart/index2.html

Jeannette

On Fri, 23 Apr 2004 13:42:53 -0700, santacruz
wrote:

Somewhere I thought I saw a 3rd mfg of threaded terminals like stalok,
norseman - anybody remember the name?


Jeannette
aa6jh
Bristol 32, San Francisco
http://www.eblw.com/contepartiro/contepartiro.html

Rusty O April 24th 04 05:38 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Hayn Enterprises in the US, made by Petersen in the UK. A full line of
stainless rigging parts, very high quality. See an assembly video at
http://www.peteresen-stainless.co.uk It really does go together that easy.
Available through West Marine by special order and others I'm sure.

Rusty O



Rusty O April 24th 04 05:38 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Hayn Enterprises in the US, made by Petersen in the UK. A full line of
stainless rigging parts, very high quality. See an assembly video at
http://www.peteresen-stainless.co.uk It really does go together that easy.
Available through West Marine by special order and others I'm sure.

Rusty O



Brian Whatcott April 24th 04 02:15 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
As a gesture to the folks at that long-time ship-building town, here's
a corrected URL:

http://www.petersen-stainless.co.uk/NewFiles/marprods.html

Brian W

On Sat, 24 Apr 2004 04:38:46 GMT, "Rusty O" wrote:

Hayn Enterprises in the US, made by Petersen in the UK. A full line of
stainless rigging parts, very high quality. See an assembly video at
http://www.petersen-stainless.co.uk It really does go together that easy.
Available through West Marine by special order and others I'm sure.

Rusty O



Brian Whatcott April 24th 04 02:15 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
As a gesture to the folks at that long-time ship-building town, here's
a corrected URL:

http://www.petersen-stainless.co.uk/NewFiles/marprods.html

Brian W

On Sat, 24 Apr 2004 04:38:46 GMT, "Rusty O" wrote:

Hayn Enterprises in the US, made by Petersen in the UK. A full line of
stainless rigging parts, very high quality. See an assembly video at
http://www.petersen-stainless.co.uk It really does go together that easy.
Available through West Marine by special order and others I'm sure.

Rusty O



Rusty O April 24th 04 07:17 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Thanks for the correction.

Rusty O



Rusty O April 24th 04 07:17 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Thanks for the correction.

Rusty O



paul martin April 25th 04 11:31 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Quick Attach is the newest and simplist.


http://bosunsupplies.com/QuickAttach.cfm

Also an article in Good Old Boat showing results of comparative tests
against Sta-Loc and Norseman

http://www.bosunsupplies.com/GoodOldBoatQuickAttach.CFM

paul martin April 25th 04 11:31 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Quick Attach is the newest and simplist.


http://bosunsupplies.com/QuickAttach.cfm

Also an article in Good Old Boat showing results of comparative tests
against Sta-Loc and Norseman

http://www.bosunsupplies.com/GoodOldBoatQuickAttach.CFM

Evan Gatehouse April 25th 04 12:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 

"Brian Whatcott" wrote in message
...


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.


--
Evan Gatehouse

you'll have to rewrite my email address to get to me
ceilydh AT 3web dot net
(fools the spammers)



Evan Gatehouse April 25th 04 12:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 

"Brian Whatcott" wrote in message
...


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.


--
Evan Gatehouse

you'll have to rewrite my email address to get to me
ceilydh AT 3web dot net
(fools the spammers)



Brian Whatcott April 25th 04 03:10 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On 25 Apr 2004 03:31:14 -0700, (paul martin)
wrote:

Quick Attach is the newest and simplist.


http://bosunsupplies.com/QuickAttach.cfm

Also an article in Good Old Boat showing results of comparative tests
against Sta-Loc and Norseman

http://www.bosunsupplies.com/GoodOldBoatQuickAttach.CFM



I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.

Brian Whatcott April 25th 04 03:10 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On 25 Apr 2004 03:31:14 -0700, (paul martin)
wrote:

Quick Attach is the newest and simplist.


http://bosunsupplies.com/QuickAttach.cfm

Also an article in Good Old Boat showing results of comparative tests
against Sta-Loc and Norseman

http://www.bosunsupplies.com/GoodOldBoatQuickAttach.CFM



I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.

Brian Whatcott April 26th 04 12:38 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.


I was certainly thinking of a Nicopress style swage. In reading the
boating press comparitive test, I understood the upper end of the test
section was nicopressed with two sleeves, and a bolted clamp.
Nicopress swages are used for light aircraft control cables
(which are safety-critical.)

Did I them misunderstand that the comparitive test was against a
swage-compressed stainless terminal?

Brian Whatcott Altus OK


Brian Whatcott April 26th 04 12:38 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.


I was certainly thinking of a Nicopress style swage. In reading the
boating press comparitive test, I understood the upper end of the test
section was nicopressed with two sleeves, and a bolted clamp.
Nicopress swages are used for light aircraft control cables
(which are safety-critical.)

Did I them misunderstand that the comparitive test was against a
swage-compressed stainless terminal?

Brian Whatcott Altus OK


Brian Whatcott April 26th 04 12:57 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK



Brian Whatcott April 26th 04 12:57 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK



Ken Heaton April 26th 04 02:01 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Comments below:

"Brian Whatcott" wrote in message
...
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings

run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try. The
double nicopress fittings could support the load imposed in the tests only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but most
was carried by the friction inherent in the eye passing around the 3" pipe.
Think of a rope around a bollard tied back to itself.
--
Ken Heaton, Cape Breton Island, Canada
kenheaton AT ess wye dee DOT eastlink DOT ca



Ken Heaton April 26th 04 02:01 AM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Comments below:

"Brian Whatcott" wrote in message
...
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.


I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings

run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try. The
double nicopress fittings could support the load imposed in the tests only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but most
was carried by the friction inherent in the eye passing around the 3" pipe.
Think of a rope around a bollard tied back to itself.
--
Ken Heaton, Cape Breton Island, Canada
kenheaton AT ess wye dee DOT eastlink DOT ca



Brian Whatcott April 26th 04 06:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 22:01:31 -0300, "Ken Heaton"
wrote:

Comments below:

"Brian Whatcott" wrote in message
.. .
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.

I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings

run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try. The
double nicopress fittings could support the load imposed in the tests only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but most
was carried by the friction inherent in the eye passing around the 3" pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

I know it doesn't sit well with people who feel they need to pay ??$80
a fitting, but Nicopress are strong and reliable enough to be used in
a more demanding role than sailboat rigging. My opinion, naturally.

Brian W

Brian Whatcott April 26th 04 06:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Sun, 25 Apr 2004 22:01:31 -0300, "Ken Heaton"
wrote:

Comments below:

"Brian Whatcott" wrote in message
.. .
On Sun, 25 Apr 2004 04:09:07 -0700, "Evan Gatehouse"
wrote:


"Brian Whatcott" wrote in message
.. .


I found this test interesting. I was surprized how well the swaged
cable performed. About as well as the best swageless.
And swages cost about 50 cents each.
These days, I take a chinese wire cutter ($15) and grind a swaging
profile in the jaws, so the extended cost at these prices is
one off $16 unit $16
ten off $25 unit $2.50
100 off $115 unit $1.15

I would very much like to know small quantity prices on all the
swageless terminals on the market - amny offers?

Brian Whatcott Altus OK
p.s. This hand swager is capable of applying excessive deformations -
easily, so a reasonable swaging jaw profile is required.

I think you might be confusing a Nicropress type sleeve (that is applied
with a lever type hand squeezer) with a swaged terminal that uses very
expensive hydraulic roller presses that squeeze the swage terminal. I've
seen Nicropress sleeves for about what you mention, but swage fittings

run
about $15 for a 1/4" for example.



I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try. The
double nicopress fittings could support the load imposed in the tests only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but most
was carried by the friction inherent in the eye passing around the 3" pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

I know it doesn't sit well with people who feel they need to pay ??$80
a fitting, but Nicopress are strong and reliable enough to be used in
a more demanding role than sailboat rigging. My opinion, naturally.

Brian W

Ken Heaton April 26th 04 10:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Question below:

"Brian Whatcott" wrote in message
...

snipped for brevity

I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try.

The
double nicopress fittings could support the load imposed in the tests

only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but

most
was carried by the friction inherent in the eye passing around the 3"

pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.


Actually, the turning couple on the pipe is counter balanced by an equal
turning couple inmposed by the dead end continuing down the other side back
to the nicopress fitting.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

I know it doesn't sit well with people who feel they need to pay ??$80
a fitting, but Nicopress are strong and reliable enough to be used in
a more demanding role than sailboat rigging. My opinion, naturally.

Brian W


I think I'm missing something here. Are you suggesting instead of using
swaged or other ends on wire terminations we use a couple of nicropress
sleeves and a large enough thimble to allow the wire to turn back on itself
without weakening it by bending it too severely? (This is how all the
terminations are done on a Laser II for instance but in that case the wires
are rather small.) Note that in the test they felt they needed a 3"
diameter pipe so as to not bend the cable too abruptly.
What then goes through the thimble to retain the end terminated thus? A pin
large enough in diameter to prevent the thimble from collapsing under load?
Or are there thimbles available, strong enough to retain their shape under
load with a small pin passing through like the one in a turnbuckle fork?
The turnbuckle fork would have to be wider than usual to accommodate the
thimble. Wouldn't this make for a rather bulky termination? We are talking
about rigging sized wire, not skinny little cables like the type used on a
light aircraft's controls.
--
Ken Heaton, Cape Breton Island, Canada
kenheaton AT ess wye dee DOT eastlink DOT ca



Ken Heaton April 26th 04 10:09 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
Question below:

"Brian Whatcott" wrote in message
...

snipped for brevity

I looked over the test description again, more carefully this time.
The description mentioned a
"C. Sherman Johnson Co. swaged terminal, with the swaged wire assembly
professionally made."

and also mentioned that in all cases, the other end was secured with
two nicopress swaged ferrules and a bolted clamp back up.

In no case, was damage to the nicopress end noted, so I have to
conclude that the double Nicopress fixing was superior to both
roller-swaged, and swageless terminals, and remarkably cheaper.

Is this reasonable, in your view?

Brian Whatcott Altus OK

No, not reasonable. I'm not great at explaining things but I'll try.

The
double nicopress fittings could support the load imposed in the tests

only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but

most
was carried by the friction inherent in the eye passing around the 3"

pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.


Actually, the turning couple on the pipe is counter balanced by an equal
turning couple inmposed by the dead end continuing down the other side back
to the nicopress fitting.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

I know it doesn't sit well with people who feel they need to pay ??$80
a fitting, but Nicopress are strong and reliable enough to be used in
a more demanding role than sailboat rigging. My opinion, naturally.

Brian W


I think I'm missing something here. Are you suggesting instead of using
swaged or other ends on wire terminations we use a couple of nicropress
sleeves and a large enough thimble to allow the wire to turn back on itself
without weakening it by bending it too severely? (This is how all the
terminations are done on a Laser II for instance but in that case the wires
are rather small.) Note that in the test they felt they needed a 3"
diameter pipe so as to not bend the cable too abruptly.
What then goes through the thimble to retain the end terminated thus? A pin
large enough in diameter to prevent the thimble from collapsing under load?
Or are there thimbles available, strong enough to retain their shape under
load with a small pin passing through like the one in a turnbuckle fork?
The turnbuckle fork would have to be wider than usual to accommodate the
thimble. Wouldn't this make for a rather bulky termination? We are talking
about rigging sized wire, not skinny little cables like the type used on a
light aircraft's controls.
--
Ken Heaton, Cape Breton Island, Canada
kenheaton AT ess wye dee DOT eastlink DOT ca



Brian Whatcott April 27th 04 03:43 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Mon, 26 Apr 2004 18:09:25 -0300, "Ken Heaton"
wrote:

Question below:


The
double nicopress fittings could support the load imposed in the tests

only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but

most
was carried by the friction inherent in the eye passing around the 3"

pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.


Actually, the turning couple on the pipe is counter balanced by an equal
turning couple imposed by the dead end continuing down the other side back
to the nicopress fitting.


Either the pipe reacts some of the tension force in the wire or it
doesn't.
If it does, the pipe will rotate unless restrained, but the upper end
needs a smaller restraining force at the nicopress to resist slip
through.
If the pipe does not resist the tension force, the force is passed to
the nicopress, where it is resisted.

But those are engineer's details.
Beneath, you make a much better, clearer argument against
Nicopress and thimbles - they are bulky, and when safety wired
as needed, are unpleasant to work around.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

///
Brian W


/// Are you suggesting instead of using
swaged or other ends on wire terminations we use a couple of nicropress
sleeves and a large enough thimble to allow the wire to turn back on itself
without weakening it by bending it too severely? (This is how all the
terminations are done on a Laser II for instance but in that case the wires
are rather small.) Note that in the test they felt they needed a 3"
diameter pipe so as to not bend the cable too abruptly.


The 3 inch pipe issue is immaterial. Engineering usage has confirmed
the value of thimbles of regular size as fit for the purpose.

What then goes through the thimble to retain the end terminated thus? A pin
large enough in diameter to prevent the thimble from collapsing under load?
Or are there thimbles available, strong enough to retain their shape under
load with a small pin passing through like the one in a turnbuckle fork?
The turnbuckle fork would have to be wider than usual to accommodate the
thimble. Wouldn't this make for a rather bulky termination? We are talking
about rigging sized wire, not skinny little cables like the type used on a
light aircraft's controls.


I like the idea of swageless terminals. How much do they cost?
I would choose them as stronger but as prettier and more functional
for the purpose

Brian W.



Brian Whatcott April 27th 04 03:43 PM

Reusable rigging wire terminals besides Stalok, Norseman?
 
On Mon, 26 Apr 2004 18:09:25 -0300, "Ken Heaton"
wrote:

Question below:


The
double nicopress fittings could support the load imposed in the tests

only
because they were clamping an eye that was passed around a 3" dia. pipe.
Some of the load on the wire was passed to each nicopress fitting but

most
was carried by the friction inherent in the eye passing around the 3"

pipe.
Think of a rope around a bollard tied back to itself.


Hmmm....you feel that the upper wire end was essentially locked to a
pipe by friction.

And so, I presume, you feel that the pipe was prevented from
rotating, because if your explanation is correct, there would be a
turning couple on the pipe.


Actually, the turning couple on the pipe is counter balanced by an equal
turning couple imposed by the dead end continuing down the other side back
to the nicopress fitting.


Either the pipe reacts some of the tension force in the wire or it
doesn't.
If it does, the pipe will rotate unless restrained, but the upper end
needs a smaller restraining force at the nicopress to resist slip
through.
If the pipe does not resist the tension force, the force is passed to
the nicopress, where it is resisted.

But those are engineer's details.
Beneath, you make a much better, clearer argument against
Nicopress and thimbles - they are bulky, and when safety wired
as needed, are unpleasant to work around.

Actually, light aircraft use double Nicopress swages, but a preferred
setup is to leave a slight loop before the second swage, in order to
observe the onset of slipping failure in the first Nicopress.
Others paint a mark at a joint.

///
Brian W


/// Are you suggesting instead of using
swaged or other ends on wire terminations we use a couple of nicropress
sleeves and a large enough thimble to allow the wire to turn back on itself
without weakening it by bending it too severely? (This is how all the
terminations are done on a Laser II for instance but in that case the wires
are rather small.) Note that in the test they felt they needed a 3"
diameter pipe so as to not bend the cable too abruptly.


The 3 inch pipe issue is immaterial. Engineering usage has confirmed
the value of thimbles of regular size as fit for the purpose.

What then goes through the thimble to retain the end terminated thus? A pin
large enough in diameter to prevent the thimble from collapsing under load?
Or are there thimbles available, strong enough to retain their shape under
load with a small pin passing through like the one in a turnbuckle fork?
The turnbuckle fork would have to be wider than usual to accommodate the
thimble. Wouldn't this make for a rather bulky termination? We are talking
about rigging sized wire, not skinny little cables like the type used on a
light aircraft's controls.


I like the idea of swageless terminals. How much do they cost?
I would choose them as stronger but as prettier and more functional
for the purpose

Brian W.