Home |
Search |
Today's Posts |
|
#1
![]() |
|||
|
|||
![]()
Bilge pump should not be wired though a battery switch. If you have a
switch that even has a "both" position, then there is a better way. House bank should be unique with a separate starting battery. A switch to parallel the starting bank to the house bank in the case of an emergency is a good idea. DOug "Roger Long" wrote in message ... In that case, you would have to leave the battery switch on both to leave the boat charging the batteries from shore power. I like the idea of being able to turn everything in the boat except the bilge pump completely off when not on it. I would have to rewire the bilge pump to the battery side to do that. That's the way I would like it but I will probably be chartering this boat eventually and I want to keep the set ups simple and standard. That's why I'm asking here what is typical. -- Roger Long "Phil Lewis" wrote in message ink.net... Typically, the chargers are on the disconnect side and not the battery side. The alternator is on the battery side. there should also be a large fuse between both and some sytems have a battery isolator too. |
#2
![]() |
|||
|
|||
![]()
It's amazing how complicated simple things are when you start thinking
about them. A little research in Calder's book shows that he, at least, considers bilge pumps on the battery side common. But.. I've already decided to run both my batteries as close to parallel as possible to minimize the depth of the discharge cycles and get maximum life out of the expensive AGM cells. This goes against the conventional wisdom of always maintaining a dedicated starting battery. I'm going against the grain because: a.. This is a sailboat and I will not be helpless if the engine doesn't start. I've cruised in boats with no engine at all. b.. The engine can be hand started, at least in warm weather. c.. I'm going to be mostly daysailing and short cruising this year. d.. I have very minimal ship's service loads so it is unlikely that I'll run the batteries flat. e.. I can start this little engine with a portable emergency battery. It's even been done with a handful of flashlight batteries. So, if I want a dead ship except for the bilge pump, I have to decide which battery to use. That means that a long run of pumping with the charger off, as could happen with the boat unattended in a storm, would drain one battery down. I also would only have half the battery capacity for bilge pumping under the same circumstances. That is not ideal. Worse, if one battery did die, I would have to get into the panel and switch the bilge pump. That's not good. I guess that, for now at least, I'll just leave things as they are with the bilge pump wired into the bus. That means leaving the switch on "Both" when putting the boat away and being sure to turn everything except the bilge pump off. A good solution for my situation would be two bilge pumps, one on each battery. That would provide redundancy. It should be simple to run a second line and another through hull in this boat. I'll just wire them into the same float switch. I'm going to take a look tomorrow. We're doing a lot of through hull work anyway and we'll have the equipment right there to punch one in above the waterline. The ramifications just go on. I just realized that the bilge discharge fitting is 3/4 and the pump hose is 1 /18. That means there is a reducer somewhere. That's a kludge I'd better track down. That would be another reason to go to two pumps of the same total capacity. -- Roger Long "Doug Dotson" dougdotson@NOSPAMcablespeedNOSPAMcom wrote in message ... Bilge pump should not be wired though a battery switch. If you have a switch that even has a "both" position, then there is a better way. House bank should be unique with a separate starting battery. A switch to parallel the starting bank to the house bank in the case of an emergency is a good idea. DOug "Roger Long" wrote in message ... In that case, you would have to leave the battery switch on both to leave the boat charging the batteries from shore power. I like the idea of being able to turn everything in the boat except the bilge pump completely off when not on it. I would have to rewire the bilge pump to the battery side to do that. That's the way I would like it but I will probably be chartering this boat eventually and I want to keep the set ups simple and standard. That's why I'm asking here what is typical. -- Roger Long "Phil Lewis" wrote in message ink.net... Typically, the chargers are on the disconnect side and not the battery side. The alternator is on the battery side. there should also be a large fuse between both and some sytems have a battery isolator too. |
#3
![]() |
|||
|
|||
![]()
I've mentioned this befo you should simply parallel the bank and
install a small starting battery. If you want it to be high quality and "idiot proof" and a battery combiner (the smaller ones are cheap. Why invest in an "emergency" starter when the same money give you a proper solution? BTW, the small Yanmar will *usually* starts with under 5 seconds of cranking, but it isn't self bleeding, so it can get balky if the line gets dirty or airbound. I just started my two engines after winter layup - one fired quickly, but the other took about 30 seconds of cranking. My point is that in real life problems always come in groups - the morning your battery dies could also be the morning the fuel filter clogs. Why rely on a pack of D cells that cost the same as a proper battery? Roger Long wrote: It's amazing how complicated simple things are when you start thinking about them. A little research in Calder's book shows that he, at least, considers bilge pumps on the battery side common. But.. I've already decided to run both my batteries as close to parallel as possible to minimize the depth of the discharge cycles and get maximum life out of the expensive AGM cells. This goes against the conventional wisdom of always maintaining a dedicated starting battery. I'm going against the grain because: a.. This is a sailboat and I will not be helpless if the engine doesn't start. I've cruised in boats with no engine at all. b.. The engine can be hand started, at least in warm weather. c.. I'm going to be mostly daysailing and short cruising this year. d.. I have very minimal ship's service loads so it is unlikely that I'll run the batteries flat. e.. I can start this little engine with a portable emergency battery. It's even been done with a handful of flashlight batteries. So, if I want a dead ship except for the bilge pump, I have to decide which battery to use. That means that a long run of pumping with the charger off, as could happen with the boat unattended in a storm, would drain one battery down. I also would only have half the battery capacity for bilge pumping under the same circumstances. That is not ideal. Worse, if one battery did die, I would have to get into the panel and switch the bilge pump. That's not good. I guess that, for now at least, I'll just leave things as they are with the bilge pump wired into the bus. That means leaving the switch on "Both" when putting the boat away and being sure to turn everything except the bilge pump off. A good solution for my situation would be two bilge pumps, one on each battery. That would provide redundancy. It should be simple to run a second line and another through hull in this boat. I'll just wire them into the same float switch. I'm going to take a look tomorrow. We're doing a lot of through hull work anyway and we'll have the equipment right there to punch one in above the waterline. The ramifications just go on. I just realized that the bilge discharge fitting is 3/4 and the pump hose is 1 /18. That means there is a reducer somewhere. That's a kludge I'd better track down. That would be another reason to go to two pumps of the same total capacity. |
#4
![]() |
|||
|
|||
![]()
I actually agree with all your points and it's probably the advice I'd
give someone else. However, I'm opting for simplicity and economy over the certainty of being able to start the engine in all circumstances. I'm not even going to invest in the emergency battery. The proper place for that, as you say, is in a box hooked up with the combiner, etc. My emergency propulsion for this year at least, will be good ground tackle and the willingness to wait for a wind. I'm going to try hand starting. If it does prove impossible I'll invest in a more sophisticated system. This is also a boat with no major electrical loads. I'll also be upgrading a lot of stuff before starting long cruises. This will be a duff around close to home and get to know the boat summer. I'll probably be spending a lot more time working on the systems than sailing. Aside from saving money, I'll have a much better idea at the end of the summer exactly what the boat needs and how I want to set up a more complex system. Even on a cruise Downeast, sailing in to anchor and rowing ashore to pick up a $40 car battery for a jump start wouldn't be a major emergency in this part of the world. Another two or three hundred dollars could be spent on much more critical things at this point than avoiding the slight possibility of that exercise. -- Roger Long "Jeff" wrote in message ... I've mentioned this befo you should simply parallel the bank and install a small starting battery. If you want it to be high quality and "idiot proof" and a battery combiner (the smaller ones are cheap. Why invest in an "emergency" starter when the same money give you a proper solution? BTW, the small Yanmar will *usually* starts with under 5 seconds of cranking, but it isn't self bleeding, so it can get balky if the line gets dirty or airbound. I just started my two engines after winter layup - one fired quickly, but the other took about 30 seconds of cranking. My point is that in real life problems always come in groups - the morning your battery dies could also be the morning the fuel filter clogs. Why rely on a pack of D cells that cost the same as a proper battery? |
#5
![]() |
|||
|
|||
![]()
Roger, I like your parallel bilge pump idea, but I'm not sure how you can
run this through one float switch as I've never heard of a DPST bilge switch. Is there such an animal available? Without it you will have difficulty isolating one battery bank from the other. I'm quite new to the sailing game and can't address many of your points, but I've risked my life and family in many other kinds of self-reliant endeavors and I've found that it is most important to rely on YOUR style of operation, not just "general practices". The row-in-for-a-quick-battery approach had me in stitches; not because I was laughing at you, but because it resembled my own unconventional, but practical, style of risk assessment: If you're not vulnerable, why be defensive! Padeen "Roger Long" wrote in message ... I actually agree with all your points and it's probably the advice I'd give someone else. However, I'm opting for simplicity and economy over the certainty of being able to start the engine in all circumstances. I'm not even going to invest in the emergency battery. The proper place for that, as you say, is in a box hooked up with the combiner, etc. My emergency propulsion for this year at least, will be good ground tackle and the willingness to wait for a wind. I'm going to try hand starting. If it does prove impossible I'll invest in a more sophisticated system. This is also a boat with no major electrical loads. I'll also be upgrading a lot of stuff before starting long cruises. This will be a duff around close to home and get to know the boat summer. I'll probably be spending a lot more time working on the systems than sailing. Aside from saving money, I'll have a much better idea at the end of the summer exactly what the boat needs and how I want to set up a more complex system. Even on a cruise Downeast, sailing in to anchor and rowing ashore to pick up a $40 car battery for a jump start wouldn't be a major emergency in this part of the world. Another two or three hundred dollars could be spent on much more critical things at this point than avoiding the slight possibility of that exercise. -- Roger Long "Jeff" wrote in message ... I've mentioned this befo you should simply parallel the bank and install a small starting battery. If you want it to be high quality and "idiot proof" and a battery combiner (the smaller ones are cheap. Why invest in an "emergency" starter when the same money give you a proper solution? BTW, the small Yanmar will *usually* starts with under 5 seconds of cranking, but it isn't self bleeding, so it can get balky if the line gets dirty or airbound. I just started my two engines after winter layup - one fired quickly, but the other took about 30 seconds of cranking. My point is that in real life problems always come in groups - the morning your battery dies could also be the morning the fuel filter clogs. Why rely on a pack of D cells that cost the same as a proper battery? |
#6
![]() |
|||
|
|||
![]()
"padeen" wrote in message
... Roger, I like your parallel bilge pump idea, but I'm not sure how you can run this through one float switch as I've never heard of a DPST bilge Yup, I just realized that with a groan. There is no substitute for sitting down and sketching out a schematic. Otherwise you end up focusing on only part of the picture as you stand in the marine supply store freaking out over how much it's going to cost you when the wife sees the credit card statement. If I weren't trying to keep battery drain parallel, I could just bring the wires of the two pumps together at the switch which has enough capacity for the amps. I'm using Rule's which (at least claim) to be very tolerant of running dry. The pumps are only a foot apart anyway. However, doing this with a pump on each battery would create a tie between the systems which would become the main battery lead if I turned the selector switch from both. FLASH BOOM! So, I'll be calling the store first thing this morning and telling them to send me another of those $40.00 switches. It's a good thing our marina lets you stay aboard because that's where I'll probably be sleeping this summer ![]() -- Roger Long |
#7
![]() |
|||
|
|||
![]()
On Sat, 07 May 2005 21:44:17 GMT, "Roger Long"
wrote: I've already decided to run both my batteries as close to parallel as possible to minimize the depth of the discharge cycles and get maximum life out of the expensive AGM cells. This goes against the conventional wisdom of always maintaining a dedicated starting battery. Modern electronic equipment can cause some annoyance/inconvenience when powered from the same battery as used to start the engine. When you start the engine, the battery voltage will drop significantly - this may be enough to turn off depth sounders and other things that have "soft" (electronic) power switches, and may cause microprocessor-based equipment to reset - your GPS may have to start from scratch re-acquiring satellites, and the radar will have to go through the 90 second warm-up routine again. Whether this is a serious problem, minor annoyance, or insignificant will depend on the equipment on board, the circumstances, and on the user.... -- Peter Bennett, VE7CEI peterbb4 (at) interchange.ubc.ca new newsgroup users info : http://vancouver-webpages.com/nnq GPS and NMEA info: http://vancouver-webpages.com/peter Vancouver Power Squadron: http://vancouver.powersquadron.ca |
#8
![]() |
|||
|
|||
![]()
After all the crap with the Capn and other trolls, it's nice to have a
discussion going on here where solid information comes back. My electronics outfit is pretty minimalist and the starting loads about as small as they get. Starting from the two battery bank shouldn't produce much drop with this little engine. This is confirmed by someone who has been running the same kind of boat for ten years this way. However, before installing radar or a hard mounted GPS, I will consider that adding a dedicated starting battery is an essential part of the installation. On this boat, I think I would go with the smaller size battery used in aircraft. If they will start the 320 cubic inch, 160 hp, engine in my 172, they ought to get this little diesel going. -- Roger Long "Peter Bennett" wrote in message news.com... On Sat, 07 May 2005 21:44:17 GMT, "Roger Long" wrote: I've already decided to run both my batteries as close to parallel as possible to minimize the depth of the discharge cycles and get maximum life out of the expensive AGM cells. This goes against the conventional wisdom of always maintaining a dedicated starting battery. Modern electronic equipment can cause some annoyance/inconvenience when powered from the same battery as used to start the engine. When you start the engine, the battery voltage will drop significantly - this may be enough to turn off depth sounders and other things that have "soft" (electronic) power switches, and may cause microprocessor-based equipment to reset - your GPS may have to start from scratch re-acquiring satellites, and the radar will have to go through the 90 second warm-up routine again. Whether this is a serious problem, minor annoyance, or insignificant will depend on the equipment on board, the circumstances, and on the user.... -- Peter Bennett, VE7CEI peterbb4 (at) interchange.ubc.ca new newsgroup users info : http://vancouver-webpages.com/nnq GPS and NMEA info: http://vancouver-webpages.com/peter Vancouver Power Squadron: http://vancouver.powersquadron.ca |
#9
![]() |
|||
|
|||
![]()
On Sat, 07 May 2005 21:44:17 GMT, "Roger Long"
wrote: e.. I can start this little engine with a portable emergency battery. It's even been done with a handful of flashlight batteries. So, if I want a dead ship except for the bilge pump, I have to decide which battery to use. That means that a long run of pumping with the charger off, as could happen with the boat unattended in a storm, would drain one battery down. I also would only have half the battery capacity for bilge pumping under the same circumstances. That is not ideal. Worse, if one battery did die, I would have to get into the panel and switch the bilge pump. That's not good. Roger, I haven't read all this thread, so this may be repetitious, but why not abandon the starter battery altogether? Your set-up sounds like a good idea for these "crankable" starters http://www.startwell.com/ http://www.springstarter.com/index.htm http://www.dieselproducts.com/spring...r/pentham.html To my mind, I would use this as the primary starter on a small marine diesel (40 HP or less=over 50% of rec. sailboats), and keep the "traditional" solenoid-style starter vacuum-packed in the bilge. Subtract the requirement to turn over a cold diesel or even an Atomic 4 like mine (which I hand-crank once a year to keep in practice...), and you can rethink a lot of your electrical needs. Food for thought, anyway. R. |
#10
![]() |
|||
|
|||
![]()
"Doug Dotson" dougdotson@NOSPAMcablespeedNOSPAMcom wrote in
: Bilge pump should not be wired though a battery switch. If you have a switch that even has a "both" position, then there is a better way. House bank should be unique with a separate starting battery. A switch to parallel the starting bank to the house bank in the case of an emergency is a good idea. DOug Great advise, Doug. Lionheart has two battery switches, side-by-side. One selects which L-16 house battery bank, normally left in BOTH and the other selects which battery (starting or house or both) is connected to the diesel starter, normally left in STARTing battery. The house connection simply connects the starting switch to the common of the house switch. Set both switches to BOTH parallels everything in the boat, the ultimate jumper cables..(c; Of course, you can switch everything to OFF to unpower it all except the permanently-connected bilge pumps and battery chargers(one for house, one for starting). Bilge pumps and chargers connect through their own safety fuse block located on the side of the house battery boxes, directly connected BOTH NEGATIVE AND POSITIVE. Bilge pumps do NOT have an OFF position, which I consider REALLY STUPID in any boat! Stalled bilge pump blows the fuse, which has a neat 12V bulb across the fuse for EASY IDENTIFICATION. It'll light up the space until you press the new fuse into the holder. Why more don't do that remains a mystery to me. As to connecting the chargers upline from the battery posts, I'm against it. The chargers have enough trouble measuring the battery's voltage because they are wired so cheap by the manufacturers...i.e. such little wires. Every time a load current passes through the wires and corrosion from the battery switch, where the charger would be connected, to the battery, this voltage drop would be measured as an increased drop in battery voltage by the charger. This screws up the charging cycles. Nope, connect the chargers directly to the battery being charged without load current carrying wires in the path. For safety, Lionheart has a 100A fuse in the jumper link between the 6V batteries in series, one on each bank. Any shorts, except directly across one battery's terminals, would simply blow the fuse, not burn the boat to the waterline. 200A on #2 is a safe limit with the switch in BOTH and Amel has master breakers where we connect our wiring to the original boat French wiring. Starting the Perkins through one 100A fuse may blow it if the engine were locked, but doesn't when it is "normal" as we tried it. If there's any power left....we can crank it...(c; Any 12/24V fuse or breaker can have a trouble light on it, easy. Just wire an indicator light ACROSS the fuses in all circuits. The current through the load that blew the fuse will light the bulb. If the bulb is full brightness, it's a pretty good indication the load has a short to negative that needs to be cleared before you blow more fuses or retrip the breaker. I like the way it shows me what fuse/breaker is tripped while we're all sitting in the dark or in a dark engine room. I use bright red indicator lights that give me plenty of light to replace the fuse, but of course they go out or go dim when you clear the short. Just turn on the load and they'll light back up so you can see the fuse holders.....cheap at any Ratshack. |
Reply |
|
Thread Tools | Search this Thread |
Display Modes | |
|
|
![]() |
||||
Thread | Forum | |||
How many voltage do i need to start my engine? | Electronics | |||
Cautionary tale | Cruising | |||
Interesting batteries | General | |||
Is it my battery or alternator that let me down? | General | |||
Deep cycle batteries - miscellaneous advice? | Electronics |