Home |
Search |
Today's Posts |
#1
![]() |
|||
|
|||
![]()
I've got a 35ft sailboat. With a 20 gallon holding tank under the
quarter berth. My vent is blocked and I can't use my head. Flushing (which I have ceased until I fix it) just expands the holding tank (not good). I found some blockage at the holding tank outlet in the tube. There was enough extra that I cut out about 3" and put it back on. Still blocked. I can crawl into the lazarette and see the hose (it's fairly translucent) but I can't detect any blockages. The tubing also has a foul odor and I want to replace it. I can't get at the vent thru-hull because it's just below the toe rail and in a spot I can just barely reach with my fingertips. I suspect it is blocked up at the thru-hull but can't prove it. I was thinking it might be easier to install a new thru-hull. I was thinking of putting the new vent in the cockpit with a SeaLand inline "holding tank vent filter" installed below decks to eliminate the chance of odors. My proposed location is in front of the helmsman's seat about 3 feet aft of the holding tank vent opening and about 8" - 10" below the toe rail level. The vent line would run aft under the quarter berth about 18" and down about 6" then make a slight turn and go up about 3 feet then turn aft and gently rise another 6" to the proposed vent thru-hull location. Does anyone have any thoughts or criticisms on this proposed method? What would Peggy say? In advance, Thanks |
#2
![]() |
|||
|
|||
![]()
On Monday 28 June 2004 8:36 pm in rec.boats.cruising Mollie wrote:
I found some blockage at the holding tank outlet in the tube. There was enough extra that I cut out about 3" and put it back on. Still blocked. It is highly likely that a blockage has built up before the on that you removed. Did you poke a suitable implement back into the tank while you had the pipe off ? -- My real address is crn (at) netunix (dot) com WARNING all messages containing attachments or html will be silently deleted. Send only plain text. |
#3
![]() |
|||
|
|||
![]()
Mollie wrote:
I've got a 35ft sailboat. With a 20 gallon holding tank under the quarter berth. My vent is blocked and I can't use my head. Flushing (which I have ceased until I fix it)... The right thing to do... just expands the holding tank (not good). Definitely not good! 'Cuz that can result in anything from an eruption in the toilet to a burst tank. I found some blockage at the holding tank outlet in the tube. There was enough extra that I cut out about 3" and put it back on. Still blocked. I can crawl into the lazarette and see the hose (it's fairly translucent) but I can't detect any blockages. Most likely it's the thru-hull that's clogged. The two most common places, especially on sailboats, are the vent fitting on the tank and the thru-hull...caused by waste spilling out the vent while heeled. The tubing also has a foul odor and I want to replace it. That won't cure any blockage in the thru-hull, but it's a good idea anyway. Use sanitation hose, not clear hose again. I can't get at the vent thru-hull because it's just below the toe rail and in a spot I can just barely reach with my fingertips. You should be able to clean it out with a screw driver blade from the outside...but you will have get to it inside the boat to replace the vent hose. I was thinking it might be easier to install a new thru-hull. Also a good idea, but you'll still have to get to the existing one from the inside of the boat to remove it and to the inside of a new one to put a new hose onto it. I was thinking of putting the new vent in the cockpit with a SeaLand inline "holding tank vent filter" installed below decks to eliminate the chance of odors. Noooo...vent filters are a bad idea on any boat because they create the very problem they're sold to solve by restricting the flow of air in and out the vent. They're also expensive--over $50/each...they only last one season at most...and they're "toast" immediately if they get wet--which makes 'em an even worse idea on sailboats that spill tank contents out the vent when heeled...and makes it impossible to flush out the vent line regularly to keep it from becoming clogged. Also, I'm not sure what you hope to accomplish by installing one...'cuz they won't cure any odor problem inside the boat, only odor out the tank vent. My proposed location is in front of the helmsman's seat about 3 feet aft of the holding tank vent opening and about 8" - 10" below the toe rail level. The vent line would run aft under the quarter berth about 18" and down about 6" then make a slight turn and go up about 3 feet then turn aft and gently rise another 6" to the proposed vent thru-hull location. Again--nooooooo! You want the tank vent line to be as SHORT and STRAIGHT as possible. Your plan has at least 3 90s in it, is at least twice as long as needs to be, and goes the wrong direction from the tank...it should go forward, not aft. What would Peggy say? Yikes! ![]() located in the boat? How far from the head? -- Peggie ---------- Peggie Hall Specializing in marine sanitation since 1987 Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and Other Sources of Aggravation and Odor" http://69.20.93.241/store/customer/p...40&cat=&page=1 http://shop.sailboatowners.com/detai...=400&group=327 |
#4
![]() |
|||
|
|||
![]()
As I said, it's a 35' sailboat with 11.5' beam. The toilet is just in
front of the starboard cockpit locker (about 9 feet from the stern). I don't have any odors or problems in the head itself aside from some minor fresh water seepage at the top of the plunger (even after installing a rebuild kit on my Raritan PHII). The holding tank is on the port side. The tank is a heavy plastic one, rectangular in shape and looks to be about 10-12" deep (est.). The current vent tube exits the holding tank on the aft end. The vent tubing goes aft further about 18" to just aft of the quarter berth. Before exiting into the lazarette it actually goes down a few inches. It exits into the lazarette and makes a fairly hard turn and goes up the inside of the hull to the thru-hull that is just below the toe rail. Thinking through the actual routing of this tubing, I imagine there is a strong possibility that the blockage could be at the turn into the lazarette being that it has the combination of being the lowest point in the line and at the same time being the location of the sharpest turn in the line. Does this explain the setup/layout enough? Peggie Hall wrote in message ... Mollie wrote: I've got a 35ft sailboat. With a 20 gallon holding tank under the quarter berth. My vent is blocked and I can't use my head. Flushing (which I have ceased until I fix it)... The right thing to do... just expands the holding tank (not good). Definitely not good! 'Cuz that can result in anything from an eruption in the toilet to a burst tank. I found some blockage at the holding tank outlet in the tube. There was enough extra that I cut out about 3" and put it back on. Still blocked. I can crawl into the lazarette and see the hose (it's fairly translucent) but I can't detect any blockages. Most likely it's the thru-hull that's clogged. The two most common places, especially on sailboats, are the vent fitting on the tank and the thru-hull...caused by waste spilling out the vent while heeled. The tubing also has a foul odor and I want to replace it. That won't cure any blockage in the thru-hull, but it's a good idea anyway. Use sanitation hose, not clear hose again. I can't get at the vent thru-hull because it's just below the toe rail and in a spot I can just barely reach with my fingertips. You should be able to clean it out with a screw driver blade from the outside...but you will have get to it inside the boat to replace the vent hose. I was thinking it might be easier to install a new thru-hull. Also a good idea, but you'll still have to get to the existing one from the inside of the boat to remove it and to the inside of a new one to put a new hose onto it. I was thinking of putting the new vent in the cockpit with a SeaLand inline "holding tank vent filter" installed below decks to eliminate the chance of odors. Noooo...vent filters are a bad idea on any boat because they create the very problem they're sold to solve by restricting the flow of air in and out the vent. They're also expensive--over $50/each...they only last one season at most...and they're "toast" immediately if they get wet--which makes 'em an even worse idea on sailboats that spill tank contents out the vent when heeled...and makes it impossible to flush out the vent line regularly to keep it from becoming clogged. Also, I'm not sure what you hope to accomplish by installing one...'cuz they won't cure any odor problem inside the boat, only odor out the tank vent. My proposed location is in front of the helmsman's seat about 3 feet aft of the holding tank vent opening and about 8" - 10" below the toe rail level. The vent line would run aft under the quarter berth about 18" and down about 6" then make a slight turn and go up about 3 feet then turn aft and gently rise another 6" to the proposed vent thru-hull location. Again--nooooooo! You want the tank vent line to be as SHORT and STRAIGHT as possible. Your plan has at least 3 90s in it, is at least twice as long as needs to be, and goes the wrong direction from the tank...it should go forward, not aft. What would Peggy say? Yikes! ![]() located in the boat? How far from the head? -- Peggie ---------- Peggie Hall Specializing in marine sanitation since 1987 Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and Other Sources of Aggravation and Odor" http://69.20.93.241/store/customer/p...40&cat=&page=1 http://shop.sailboatowners.com/detai...=400&group=327 |
#5
![]() |
|||
|
|||
![]()
Side comment that I forgot from the previous post. It released the
built up pressure from the tank quickly when I took the vent tube off the holding tank. I also verified that the vent was clear going back into the holding tank when I removed the vent tube. I used a screwdriver and there was nothing there. Peggie Hall wrote in message ... Mollie wrote: I've got a 35ft sailboat. With a 20 gallon holding tank under the quarter berth. My vent is blocked and I can't use my head. Flushing (which I have ceased until I fix it)... The right thing to do... just expands the holding tank (not good). Definitely not good! 'Cuz that can result in anything from an eruption in the toilet to a burst tank. I found some blockage at the holding tank outlet in the tube. There was enough extra that I cut out about 3" and put it back on. Still blocked. I can crawl into the lazarette and see the hose (it's fairly translucent) but I can't detect any blockages. Most likely it's the thru-hull that's clogged. The two most common places, especially on sailboats, are the vent fitting on the tank and the thru-hull...caused by waste spilling out the vent while heeled. The tubing also has a foul odor and I want to replace it. That won't cure any blockage in the thru-hull, but it's a good idea anyway. Use sanitation hose, not clear hose again. I can't get at the vent thru-hull because it's just below the toe rail and in a spot I can just barely reach with my fingertips. You should be able to clean it out with a screw driver blade from the outside...but you will have get to it inside the boat to replace the vent hose. I was thinking it might be easier to install a new thru-hull. Also a good idea, but you'll still have to get to the existing one from the inside of the boat to remove it and to the inside of a new one to put a new hose onto it. I was thinking of putting the new vent in the cockpit with a SeaLand inline "holding tank vent filter" installed below decks to eliminate the chance of odors. Noooo...vent filters are a bad idea on any boat because they create the very problem they're sold to solve by restricting the flow of air in and out the vent. They're also expensive--over $50/each...they only last one season at most...and they're "toast" immediately if they get wet--which makes 'em an even worse idea on sailboats that spill tank contents out the vent when heeled...and makes it impossible to flush out the vent line regularly to keep it from becoming clogged. Also, I'm not sure what you hope to accomplish by installing one...'cuz they won't cure any odor problem inside the boat, only odor out the tank vent. My proposed location is in front of the helmsman's seat about 3 feet aft of the holding tank vent opening and about 8" - 10" below the toe rail level. The vent line would run aft under the quarter berth about 18" and down about 6" then make a slight turn and go up about 3 feet then turn aft and gently rise another 6" to the proposed vent thru-hull location. Again--nooooooo! You want the tank vent line to be as SHORT and STRAIGHT as possible. Your plan has at least 3 90s in it, is at least twice as long as needs to be, and goes the wrong direction from the tank...it should go forward, not aft. What would Peggy say? Yikes! ![]() located in the boat? How far from the head? -- Peggie ---------- Peggie Hall Specializing in marine sanitation since 1987 Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and Other Sources of Aggravation and Odor" http://69.20.93.241/store/customer/p...40&cat=&page=1 http://shop.sailboatowners.com/detai...=400&group=327 |
#6
![]() |
|||
|
|||
![]() Mollie wrote: As I said, it's a 35' sailboat with 11.5' beam....The holding tank is on the port side. The tank is a heavy plastic one, rectangular in shape and looks to be about 10-12" deep (est.)... Where is the tank located, Mollie? On some 35.5 Beneateaus, it's just aft of the head, in the port lazarette at the forward end of the cockpit. If that's where yours is, the vent thru-hull should be right next the tank and the line should go straight to it, using an elbow fitting on the tank. That would give you a straight vent line less than 2' long. From your description it even sounds like that's actually where the thru-hull is...but the vent line takes a "tour of the boat" to get from the tank to it. So you may only need to replace your current line with one that goes directly to the current thru-hull in straight line to solve your problem. If that's not where the tank is, it shouldn't be too hard for you to figure out where a new thru-hull has to go to give you a short straight line from the tank to it. The current vent tube exits the holding tank on the aft end. The vent tubing goes aft further about 18" to just aft of the quarter berth. Before exiting into the lazarette it actually goes down a few inches. That's a problem...'cuz any sag in the vent line is a place where water or waste can pool and block the vent. It exits into the lazarette and makes a fairly hard turn and goes up the inside of the hull to the thru-hull that is just below the toe rail. Thinking through the actual routing of this tubing, I imagine there is a strong possibility that the blockage could be at the turn into the lazarette being that it has the combination of being the lowest point in the line and at the same time being the location of the sharpest turn in the line. That's a good possibility. Water can create a barrier, but it can be blown out...but any waste will harden and build up till makes real "plug" in the line. You don't want ANY low spots in a holding tank vent line. It released the built up pressure from the tank quickly when I took the vent tube off the holding tank. You're lucky it didn't spray waste all over everything including you! ![]() Never disconnect a hose if you suspect a blocked vent/pressurized tank until AFTER you've relieved any pressure by loosening the deck pumpout cap. Have a hose at the ready...'cuz if the tank is pressurized, waste as well as air can start to ooze out as soon as the cap is loose enough to allow to escape. And hang on tight to the cap, 'cuz if the tank is seriously pressurized, the pressure can spin it the rest of the way off once it's loosened a little. Loosening the cap is also the easiest way to confirm that vent IS blocked. (Another clue, btw, is any hissing sound in the head as the tank is being pumped out...that's a sign that the vent isn't supplying enough air--that air is being pulled into the tank through any other source available). I also verified that the vent was clear going back into the holding tank when I removed the vent tube. I used a screwdriver and there was nothing there. Check the thru-hull too...that's the most common place for a tank vent blockage. You could even have two--one in the low spot in the hose and one there. Meanwhile, don't try to pump out till you have an open vent (even if that's just the fitting on the tank with no hose attached)...'cuz a pumpout pulling against a blocked vent can crack a tank. Peggie ---------- Peggie Hall Specializing in marine sanitation since 1987 Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and Other Sources of Aggravation and Odor" http://69.20.93.241/store/customer/p...40&cat=&page=1 |
#7
![]() |
|||
|
|||
![]()
I was able to replace the vent tube. I guess my old bones were able
to fit in smaller spaces than I thought. The thru-hull wasn't blocked. Things are much improved. I still need to replace the pump-out tubing and the tubing coming from the head itself. There is still some mild odor. I also need to find a solution to the low spot in the vent tube. I'll reroute that tube in some fashion so that I eliminate the low spot. When I do, I should also be able to remove most of the bend in that vent line when it enters the lazarette. I want to thank everyone for their assistance and advice. |