View Single Post
  #6   Report Post  
Peggie Hall
 
Posts: n/a
Default Holding Tank Monitors

Marc wrote:
Hi Peggie, while I got you on the line, I'm going with the Ronco B126
30 gal. Two 1.5" dip tubes, 1.5" fill, 3/4" vent., all top mounted.
With the idea of keeping the number of penetrations to a minimum, is
it necessary to have a clean out port? If yes, how about just a 3"
boss with a plug instead of a port and plate?


Hi Marc (oops...I still owe you a fax and an email)...

That sounds fine to me, except that I'd go with a 1" vent instead of
3/4". The clean-out port that Ronco installs IS a 3" boss with threaded
cap. You can get 4" or even 6" if you want.

Peggie
----------
Peggie Hall
Specializing in marine sanitation since 1987
Author "Get Rid of Boat Odors - A Guide To Marine Sanitation Systems and
Other Sources of Aggravation and Odor"
http://www.seaworthy.com/html/get_ri...oat_odors.html