View Single Post
  #9   Report Post  
Steve Lusardi
 
Posts: n/a
Default Fuel Tank Construction

5052 is a marine grade aluminum, but aluminum of any type is very reactive
when exposed and unprotected. I suggest that these tanks, once installed
will not offer access to all surfaces impeding inspection and maintenance.
In that light, I would not use it. 316TI is the chemical industry's material
of choice for corrosive environments. It is correct that SS will corrode
(crevise corrosion), but that takes stagnant water without oxygen and that
case will not exist is this application. If all welds are properly
passivated, inside and out, then there should be no corrosion. However by
far, the majority of diesel tanks are made very successfully of mild steel.
The success of mild steel is significantly enhanced when the INSIDE of the
tank is coated with this permatex product. This paint was developed for the
USAF for their underground jet fuel storage tanks. It is sold by the kilo
and has a 30 day shelf life. This has a very high lead content and is
hazardous to apply. Proper breathing gear is a must. It is sold to
professionals only. Another solution for these tanks would be polypropylene.
It can be welded, so custom fabrications are very possible and static
electricity and corrosion are not a problem. I believe all Chrysler vehicles
now use this. As a cost, I would estimate $3000 to $4000 per tank would be
close. Just as a side item, I use mild steel for diesel and 316TI for
drinking water.
Steve

"habbi" wrote in message
...
I was told 5052 aluminum is better than any stainless, and that stainless
tends to stress crack. I am sure there are many perfectly good stainless

and
aluminum tanks out there. I would not even think about mild steel, it will
eventually start to rust.

"Wayne.B" wrote in message
...
On Sat, 5 Jun 2004 07:08:12 +0200, "Steve Lusardi"
wrote:
Wayne, you are talking about a reasonable effort and significant cost
regardless of the material chosen, Do not use aluminum, it is far too
reactive. Do not use gavanized steel. The diesel will disolve the zinc.

The
ultimate material should be 316TI SS and next best would be mild steel
blasted and painted with the special Permatex tank paint. This paint is
designed for large storage tanks and must be ordered specially. I just
finished 2 water tanks slightly smaller than yours in stainless and the
material cost was $3200 and that included access hatches.

=============================

Steve, a couple of questions:

1. Dou you use the Permatex both inside and out? Manufacturer?

2. I've always heard that SS tanks for diesel were a problem because
of weld corrosion. Is that not a problem with 316TI?