View Single Post
  #10   Report Post  
posted to rec.boats.cruising
[email protected] tsmwebb@gmail.com is offline
external usenet poster
 
First recorded activity by BoatBanter: Sep 2006
Posts: 859
Default Standing rigging - stress calculations

On Jan 31, 12:47 pm, "Roger Long" wrote:
... there are limits to degree of precision that can be expected in
newsgroup posts. I should have said "loads in addition to pre-tensioning
and weight". ...


I believe that shrouds are sized to about 3x the expected static load
per wire at 30 degrees heel and headstays around 15 times. This seems
to put the two types of stay into noticeably different categories when
doing stress calcs. I'm with you on newsgroup expectations, of
course. Though, as I mentioned before, there is a very complete
discussion of how to do these calcs including a worked example in
Larsson & Eliasson's book.

-- Tom.