Thread
:
stainless steel foil instead of copper for grounding Ham radio?
View Single Post
#
9
posted to rec.boats.cruising
Bruce in Alaska[_2_]
external usenet poster
First recorded activity by BoatBanter: Oct 2007
Posts: 16
stainless steel foil instead of copper for grounding Ham radio?
In article ,
wrote:
To obtain capacitance coupling to the ocean the plate has only to be
below the external water line and I have not seen too many boats with
bilge water that high.
Further if the plate is only acting as the ground plane in an antenna
system then to avoid electrolyses the RF ground should be connected to
the plate through high voltage capacitors thus no DC current on the
plate.
If connections are made with proper tin plated wire and terminals
there is no reason that corrosion should be any more a problem then
with any other electrical systems mounted below the cabin sole.
Bruce in Bangkok
(brucepaigeATgmailDOTcom)
If the "Plate" is to used to be one side of a Capacative Coupling
for the RF Grounding of an MF/HF Antenna System, then your "Best
Solution" is to use a material with the Lowest Resistance, Highest
Surface Area, encase it in the Thinest Dielectric Insulating
Film available, and mount it as close as possible to the SeaWater.
No High Voltage Capacitor, required, as the Dielectric Film will
be the DC Current Insulator.
Bruce in alaska
--
add path before @
Reply With Quote
Bruce in Alaska[_2_]
View Public Profile
Find all posts by Bruce in Alaska[_2_]