Jeff wrote:
I've often wondered it this setup requires a "lock" on the pumpout to
comply with 33CFR159.


It doesn't...Only valves and/or seacocks connected to overboard
discharge thru-hulls must be secured:

33CFR159 sayeth:


(c) When operating a vessel on a body of water where the discharge of
untreated sewage is prohibited by the Environmental Protection Agency
under 40 CFR 140.3, the operator must secure each Type III device in a
manner which prevents discharge of sewage. Acceptable methods of
securing the device include—

(1) Closing each valve leading to an overboard discharge and removing
the handle;

(2) Padlocking each valve leading to an overboard discharge in the
closed position; or

(3) Using a non-releasable wire-tie to hold each valve leading to an
overboard discharge in the closed position.

No mention of the pumpout line at all.

However, inland may be another story. The Great Lakes and all non-navigable
inland lakes are “no discharge” waters. They’re also a loooong way
from the ocean. Since there's no possible way to legally use a
y-valve or macerator to dump a tank, many states have made it illegal
for vessels operating on these waters even to have one or both
installed. When in doubt, check with your local authorities.


Most descriptions of the reg refer to "preventing
accidental discharge" or securing a "direct discharge" line.


There are no adjectives in the wording of the CFR (which I copy/pasted
directly from it above)...just "discharge."

If the holding tank is considered part of the MSD Type
III system, then it would seem its pumping system would be included.


Any means of pumping sewage overboard IS included. The CFR defines
"discharge" as: "includes, but is not limited to, any spilling, leaking,
pouring, pumping, emitting, emptying, or dumping." The deck pumpout
fitting would automatically be "secure" as long as no hose going over
the side is connnected to it.


--