DSK wrote:
Jeff Morris wrote:


Consider, for a 80 foot round trip and an 80 Amp load, you want "2"
gauge wire
for a 10% loss.



I think that's a bit on the light side. Most charts only show wire run
lengths up to 60' and a medium size windlass is going to be a 100 amp
load anyway.

A 10% voltage drop is significant. Might knock other things off line,
especially any digital devices. I'd prefer to size things for a lower
voltage drop anyway, where practical.


The voltage drop will be at the motor, not the house battery end.

Cheers