Gordon January 13th 08 09:17 PM

Lifelines for RF counterpoise?
 

Would there be any potential harmful voltages with respect to the
boats ground?
Would it be a sufficient RF counterpoise?
If the lines were tied to boats ground, would this introduce RF on
the boats ground causing possible interference?
Thanks
Gordon

chuck January 14th 08 12:54 AM

Lifelines for RF counterpoise?
 
On Sun, 13 Jan 2008 13:17:05 -0800, Gordon wrote:


Would there be any potential harmful voltages with respect to the
boats ground?
Would it be a sufficient RF counterpoise?
If the lines were tied to boats ground, would this introduce RF on
the boats ground causing possible interference?
Thanks
Gordon


Usually, the lifelines are bonded to the boat's AC and DC ground, as
are any metal tanks, the engine, etc. If that is done, there shouldn't
be any harmful voltages present at the lifelines.

When the metal objects are bonded to form the counterpoise, that is
often sufficient. On sal****er, your boat's ground system is usually
connected galvanically to the sea as well. Over land or fresh water,
the counterpoise is more critical.

I assume you mean interference to other electronic systems.
Interference can occur with almost any antenna system on a small boat.
What you are contemplating is no more likely to cause problems than
the alternatives. The best approach is to give it a try.

Good luck.

Chuck

----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----

[email protected] January 14th 08 07:46 AM

Lifelines for RF counterpoise?
 
On Jan 13, 2:54 pm, Chuck wrote:
... Usually, the lifelines are bonded to the boat's AC and DC ground ...


Really? Yeah, they probably ought to be and maybe ABYS says they
should be but I don't think it is common practice.

-- Tom.

chuck January 14th 08 12:35 PM

Lifelines for RF counterpoise?
 
On Sun, 13 Jan 2008 23:46:52 -0800 (PST), "
wrote:

On Jan 13, 2:54 pm, Chuck wrote:
... Usually, the lifelines are bonded to the boat's AC and DC ground ...


Really? Yeah, they probably ought to be and maybe ABYS says they
should be but I don't think it is common practice.

-- Tom.


Thanks, Tom. You are correct. I meant that when the lifelines are used
as an RF counterpoise they are usually bonded . . .

Chuck

----== Posted via Newsfeeds.Com - Unlimited-Unrestricted-Secure Usenet News==----
http://www.newsfeeds.com The #1 Newsgroup Service in the World! 120,000+ Newsgroups
----= East and West-Coast Server Farms - Total Privacy via Encryption =----

[email protected] January 14th 08 05:24 PM

Lifelines for RF counterpoise?
 
On Jan 14, 2:35 am, Chuck wrote:
... I meant that when the lifelines are used
as an RF counterpoise they are usually bonded . ...


Oh, yes, that makes sense. I should have gotten that from your
original post. Thanks for the clarification.

-- Tom.