Windlass Electrical Connection
I am considering adding a electric windlass to my boat and I would like some
opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
Why add the extra weight f a battery in the front where you don't want it?
I'd use heavy gauge wire and run it from the house bank. Ray Cullum wrote I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
I never bought the logic, neither did my builder, who used the "long wire"
approach. Consider, for a 80 foot round trip and an 80 Amp load, you want "2" gauge wire for a 10% loss. Being conservative, you might go to "0" gauge. That 80 feet weighs 35 pounds. So the result is you would put a 35 pound starting battery in the bow instead of distributing 35 pounds along the length. And we're not talking about all the complications of keeping an extra battery charged and happy. The only virtue is that you now have some redundancy in a critical area. But you also have another failure mode. There are other issues, like how do you prevent 80 amps from going down the charger wire if you raise the anchor when the engine is running? And if you don't keep up with the use, how large a battery to you need to ensure you have the juice to reset the anchor several times, the last time, of course, in the middle of the night? "Ray Cullum" wrote in message ... I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
He doesn't say, but if he's adding a windless, he's probably adding an
all chain rode and he is probably a cruiser. The added weight of a battery forward (it doesen't have to be in the extreme pointy end) is negligable when considered with all the other gear he is carrying. Electrically it makes sense and he doesnt even need another output on the charger, he can use a battery combiner. http://www.yandina.com/ Also, if the battery would be 40' from a 700 amp battery bank, I suggest he's got a big enough platform. On Tue, 27 Jul 2004 16:17:14 GMT, "Bart Senior" wrote: Why add the extra weight f a battery in the front where you don't want it? I'd use heavy gauge wire and run it from the house bank. Ray Cullum wrote I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
Would it make any difference on a boat that large? I think it wouldn't
be a bad thing to have another bat. Also seems like a lot less work, hassle. Either would work though. -- "j" ganz @@ www.sailnow.com "Bart Senior" wrote in message et... Why add the extra weight f a battery in the front where you don't want it? I'd use heavy gauge wire and run it from the house bank. Ray Cullum wrote I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
"Marc" wrote in message
... He doesn't say, but if he's adding a windless, he's probably adding an all chain rode Why? Many (most? virtually all?) windlasses now handle rope/chain pretty well. Certainly there a class of cruiser that prefers all-chain, but I'm not sure this represents the majority. and he is probably a cruiser. True, a racer would have an FX-7 The added weight of a battery forward (it doesen't have to be in the extreme pointy end) is negligable when considered with all the other gear he is carrying. Actually, it might be more than the chain. I have 50 pounds of chain, and a 35 pound windlass. I'm glad I don't have another 50 pounds of battery up there. Of course, my cat is a bit weight sensitive, so this is an issue for me. Electrically it makes sense Why? and he doesnt even need another output on the charger, he can use a battery combiner. http://www.yandina.com/ Also, if the battery would be 40' from a 700 amp battery bank, I suggest he's got a big enough platform. On Tue, 27 Jul 2004 16:17:14 GMT, "Bart Senior" wrote: Why add the extra weight f a battery in the front where you don't want it? I'd use heavy gauge wire and run it from the house bank. Ray Cullum wrote I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC |
Windlass Electrical Connection
Jeff Morris wrote:
I never bought the logic, neither did my builder, who used the "long wire" approach. IMHO there are benefits to both approaches, but to choose one over the other, you need to do some careful math. Consider, for a 80 foot round trip and an 80 Amp load, you want "2" gauge wire for a 10% loss. I think that's a bit on the light side. Most charts only show wire run lengths up to 60' and a medium size windlass is going to be a 100 amp load anyway. A 10% voltage drop is significant. Might knock other things off line, especially any digital devices. I'd prefer to size things for a lower voltage drop anyway, where practical. ... Being conservative, you might go to "0" gauge. That 80 feet weighs 35 pounds. So the result is you would put a 35 pound starting battery in the bow instead of distributing 35 pounds along the length. And we're not talking about all the complications of keeping an extra battery charged and happy. The only virtue is that you now have some redundancy in a critical area. But you also have another failure mode. Either way you go, yo have another failure mode possible. If there is a short somewhere along the 80' wiring run, the lack of resistance will kill your whole battery bank really quick, and possibly leave scorch marks. There are other issues, like how do you prevent 80 amps from going down the charger wire if you raise the anchor when the engine is running? And if you don't keep up with the use, how large a battery to you need to ensure you have the juice to reset the anchor several times, the last time, of course, in the middle of the night? Well, how do you insure that your house bank isn't drained by resetting the anchor in the middle of the night? How do you feel about sawing holes in bulkheads to run two passes of #0 cable (or bigger) with looming of course? How about running that big a load to ground and putting back voltage spike on everything else in your 12V system? There are plusses and minusses to both running cable and putting in a dedicated windlass battery. IMHO Ray's case is just over the edge where it looks like a good case for a dedicated windlass battery. Fresh Breezes- Doug King |
Windlass Electrical Connection
You do raise some interesting points, though I don't think any of them are even
close to the downside of an extra battery. For instance, you still need a fairly large wire run to deal with, though not 1/0. And how do you prevent that from melting if it ends up carrying the windlass load. BTW, all windlass connections should be through an appropriate breaker, and should be turned off when not used - you certainly don't want to start the windlass going if you're stumbling around the foredeck and trip on a switch! Scorching should not be a possibility in any proper setup. The house bank won't get run down (hopefully) because its monitored by an AmpHour meter, and since the odds are high one will be powering for at least a few minutes before or after setting or hauling, there should be not problem. A dedicated battery could have a problem that goes un-noticed until total failure. If spiking is a concern, the windlass could be wired not to the house bank, but to the starter battery. "DSK" wrote in message ... Jeff Morris wrote: I never bought the logic, neither did my builder, who used the "long wire" approach. IMHO there are benefits to both approaches, but to choose one over the other, you need to do some careful math. Consider, for a 80 foot round trip and an 80 Amp load, you want "2" gauge wire for a 10% loss. I think that's a bit on the light side. Most charts only show wire run lengths up to 60' and a medium size windlass is going to be a 100 amp load anyway. A 10% voltage drop is significant. Might knock other things off line, especially any digital devices. I'd prefer to size things for a lower voltage drop anyway, where practical. ... Being conservative, you might go to "0" gauge. That 80 feet weighs 35 pounds. So the result is you would put a 35 pound starting battery in the bow instead of distributing 35 pounds along the length. And we're not talking about all the complications of keeping an extra battery charged and happy. The only virtue is that you now have some redundancy in a critical area. But you also have another failure mode. Either way you go, yo have another failure mode possible. If there is a short somewhere along the 80' wiring run, the lack of resistance will kill your whole battery bank really quick, and possibly leave scorch marks. There are other issues, like how do you prevent 80 amps from going down the charger wire if you raise the anchor when the engine is running? And if you don't keep up with the use, how large a battery to you need to ensure you have the juice to reset the anchor several times, the last time, of course, in the middle of the night? Well, how do you insure that your house bank isn't drained by resetting the anchor in the middle of the night? How do you feel about sawing holes in bulkheads to run two passes of #0 cable (or bigger) with looming of course? How about running that big a load to ground and putting back voltage spike on everything else in your 12V system? There are plusses and minusses to both running cable and putting in a dedicated windlass battery. IMHO Ray's case is just over the edge where it looks like a good case for a dedicated windlass battery. Fresh Breezes- Doug King |
Windlass Electrical Connection
In article , Ray Cullum
wrote: I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. You've seen the other replies and the pros/cons. For a different perspective, have you considered hydraulics? Keep the motor near the battery bank and run the hydraulic lines to the winch. You can get 12V DC motors & pumps, run a pump off your main engine via a magnetic clutch or even a 110V AC motor via invertor. This is fishing boat tech, not yacht, so of course it may not be as elegant but it will work much more reliably. I think 12V DC anchor winches are inventions designed to kill batteries and fail when most needed. PDW |
Windlass Electrical Connection
DSK wrote: Jeff Morris wrote: Consider, for a 80 foot round trip and an 80 Amp load, you want "2" gauge wire for a 10% loss. I think that's a bit on the light side. Most charts only show wire run lengths up to 60' and a medium size windlass is going to be a 100 amp load anyway. A 10% voltage drop is significant. Might knock other things off line, especially any digital devices. I'd prefer to size things for a lower voltage drop anyway, where practical. The voltage drop will be at the motor, not the house battery end. Cheers |
Windlass Electrical Connection
Nav wrote:
The voltage drop will be at the motor, not the house battery end. If you have a 10% voltage drop at the motor, there will be a noticable drop at the battery terminals too. Ever notice the way an ammeter swings when you turn the starter? Hint: very few cars wire the ammeter sensor leads to the starter terminals. DSK |
Windlass Electrical Connection
What Nav is saying is there will be a 10% drop across the wire itself. This is
on top of the serious drop caused by the 100 Amp load on the house bank. Of course, the engine will likely be running, so the load might be partially offset, depending on how the alternator behaves at low rpm. BTW, my system has the windlass and inverter (i.e. microwave) off the house bank. A few times I've noticed the affect of the voltage drops, especially if it goes below 12, but I've never been "spiked." "DSK" wrote in message ... Nav wrote: The voltage drop will be at the motor, not the house battery end. If you have a 10% voltage drop at the motor, there will be a noticable drop at the battery terminals too. Ever notice the way an ammeter swings when you turn the starter? Hint: very few cars wire the ammeter sensor leads to the starter terminals. DSK |
Windlass Electrical Connection
an isolating relay on the charging line should do it (i.e., normally closed
switch in the charging line that opens whenever the windlass is powered. "Jeff Morris" wrote {snip} There are other issues, like how do you prevent 80 amps from going down the charger wire if you raise the anchor when the engine is running? |
Windlass Electrical Connection
|
Windlass Electrical Connection
Jeff Morris wrote:
What Nav is saying is there will be a 10% drop across the wire itself. OK, I did not read that into what he wrote. ... This is on top of the serious drop caused by the 100 Amp load on the house bank. Sure. You know that and I know that, but... Of course, the engine will likely be running, so the load might be partially offset, depending on how the alternator behaves at low rpm. That's true, and it makes it more complicated to wire a charger to a dedicated windlass battery. BTW, my system has the windlass and inverter (i.e. microwave) off the house bank. A few times I've noticed the affect of the voltage drops, especially if it goes below 12, but I've never been "spiked." Our inverter gets very unhappy and makes loud unhappy beeping noises, at a frequency that loosens your fillings, if the voltage drops below it's comfort zone. If the drop is large, it will shut off. That's the only fancy electronics we have at present, but I understand a lot of things (like radios) show signs of distress with low voltage. bad for motors too. Of course good electronics will have a low votlage shut-off. We ae planning to install a new bigger house bank and a windlass in the near future, I'm still studying how I want to do it. Fresh Breezes- Doug King |
Windlass Electrical Connection
Electronics are rarely damaged by low voltage. Of much greater concern
is the switching of inductive loads (like motors) which cause voltage spikes. Good capacitive supression at the motor is a very good idea if you value your electronics. In this regard, the resistance of the wire to the motor can be considered a protective element. Cheers DSK wrote: Jeff Morris wrote: What Nav is saying is there will be a 10% drop across the wire itself. OK, I did not read that into what he wrote. ... This is on top of the serious drop caused by the 100 Amp load on the house bank. Sure. You know that and I know that, but... Of course, the engine will likely be running, so the load might be partially offset, depending on how the alternator behaves at low rpm. That's true, and it makes it more complicated to wire a charger to a dedicated windlass battery. BTW, my system has the windlass and inverter (i.e. microwave) off the house bank. A few times I've noticed the affect of the voltage drops, especially if it goes below 12, but I've never been "spiked." Our inverter gets very unhappy and makes loud unhappy beeping noises, at a frequency that loosens your fillings, if the voltage drops below it's comfort zone. If the drop is large, it will shut off. That's the only fancy electronics we have at present, but I understand a lot of things (like radios) show signs of distress with low voltage. bad for motors too. Of course good electronics will have a low votlage shut-off. We ae planning to install a new bigger house bank and a windlass in the near future, I'm still studying how I want to do it. Fresh Breezes- Doug King |
Windlass Electrical Connection
Good suggestion! A family friend died when an auto battery
exploded. -- "j" ganz @@ www.sailnow.com "Joe" wrote in message om... (Ray Cullum) wrote in message ... I am considering adding a electric windlass to my boat and I would like some opinions on the best way to connect to the electrical system. The windlass will be approximately 40 feet from my house battery bank which is 700amps. It has been suggested to me to place a small battery up close to the windlass so you don't have to run heavy battery cable such a distance and sustain the power loss. Small cable could be run to the battery strictly for recharging. Thanks for the help. Ray Cullum S/V FROLIC Weight is not an issue. Having an extra battery just for a winch is a good ideal as long as you can properly ventilate the compartment. Ive seen more diesel boats blow up due to battery gas than any other reason. Joe |
Windlass Electrical Connection
I don't know the circumstances other than he was trying
to jump a dead battery. It was many years ago. -- "j" ganz @@ www.sailnow.com OzOne wrote in message ... On Wed, 28 Jul 2004 21:44:58 -0700, "Jonathan Ganz" scribbled thusly: Good suggestion! A family friend died when an auto battery exploded. Hmmm, often because it was low on water and arced internally. Oz1...of the 3 twins. I welcome you to crackerbox palace,We've been expecting you. |
Windlass Electrical Connection
On Wed, 28 Jul 2004 21:44:58 -0700, "Jonathan Ganz"
wrote this crap: Good suggestion! A family friend died when an auto battery exploded. Liar. You have no friends. Pathetic Earthlings! No one can save you now! |
Windlass Electrical Connection
Good one Horass, you're getting better.
-- "j" ganz @@ www.sailnow.com "Horvath" wrote in message ... On Wed, 28 Jul 2004 21:44:58 -0700, "Jonathan Ganz" wrote this crap: Good suggestion! A family friend died when an auto battery exploded. Liar. You have no friends. Pathetic Earthlings! No one can save you now! |
All times are GMT +1. The time now is 09:25 PM. |
Powered by vBulletin® Copyright ©2000 - 2025, Jelsoft Enterprises Ltd.
Copyright ©2004 - 2014 BoatBanter.com